Bunn H5E Water Heater User Manual


 
16
SERVICE (cont.)
Limit Thermostat
Location:
The limit thermostat is located on the tank lid.
To test the limit thermostat, access will also be needed
to the terminal block located at the rear of the dispenser.
If voltage was present as described, reconnect the black
wire and proceed to #5.
If voltage was not present as described, refer to the
Wiring Diagrams and check the dispenser wiring har-
ness.
5. Check for continuity across the terminals of the
limit thermostat.
If continuity is not present as described, the circuit is
broken. Press the reset button of the limit thermostat
and recheck for continuity.
If continuity is not present as described, replace the
limit thermostat.
Removal and Replacement:
1. Remove both wires from the limit thermostat ter-
minals.
2. Remove the two #10-32 nuts attaching the limit
thermostat to the top of the tank.
3. Install the new limit thermostat and secure into
place with two #10-32 nuts.
4. Refer to FIG. 7 when reconnecting the wires.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. There are two black wires on the limit thermostat
terminals. One comes from the terminal block. The
other goes directly to the tank heater terminal.
Remove the black wire at the limit thermostat com-
ing from the terminal block.
3. Check the voltage across the black wire removed
from the limit thermostat and the white wire or red
wire of the terminal block with a voltmeter. Con-
nect the dispenser to the power source. The indi-
cation must be:
a.) 100 to 120 volts ac for 100 to 120 volt models
or
b.) 200 to 240 volts ac for 200 to 240 volt models
or
c.) 230 volts ac for 230 volt models.
4. Disconnect the dispenser from the power source.
FIG. 6 LIMIT THERMOSTAT
FIG. 7 LIMIT THERMOSTAT WIRING
BLK to Terminal Block
BLK to Tank Heater
P1772
P1776
Reset
10420 091902