PLUMBING REQUIREMENTS
This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 90 psi
(138 and 620 kPa) from a
1
2" or larger supply line. A shut-off valve should be installed in the line before the dis-
penser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345
kPa). The water inlet fi tting is
1
4" fl are.
NOTE - Bunn-O-Matic recommends
1
4" copper tubing for installations of less than 25 feet and
3
8" for more than
25 feet from the
1
2" water supply line. At least 18 inches of an FDA approved fl exible beverage tubing, such as
reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop.
It can be purchased direct from Bunn-O-Matic (part number 00326-0000). Bunn-O-Matic does not recommend
the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this
type of device may restrict water fl ow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building
Offi cials and Code Administrators International, Inc. (BOCA) and the Food Service Sanita-
tion Manual of the Food and Drug Administration (FDA). For models installed outside the
U.S.A., you must comply with the applicable Plumbing/Sanitation Code for your area.
PLUMBING HOOK UP
1. Remove the shipping cap from the fi tting on the rear of the dispenser, Fig 3.
2. Attach the fl are elbow fi tting (supplied separately with the dispenser) to the fi tting.
3. Flush the water line and securely attach it to the fl are elbow fi tting.
4. Turn on the water supply.