Bunn H5E-DV PC Water Heater User Manual


 
9
3. Press and release the center button once more. The display will read H2, then show
either FAH (Degrees in Fahrenheit) or Cen (Degrees in Centigrade).
4. Use the (+) and (-) buttons to alternate between FAH and CEn.
5. Press and release the center button once more. The display will read H3, then show
(- - -).
6. Press and hold both (+) and (-) buttons to initiate the resetting of the factory de-
fault settings. The display (- - -) will fl ash on and off during this time (about 5 to 7
seconds).
7. When the factory default numbers are loaded in, the display will stop fl ashing, then
read don (DONE). You can now release the two buttons.
NOTE: If you release the two buttons at any time before the display reads don, the Factory Default numbers will
not be entered. The old numbers will remain in the memory.
8. To exit Level 2 Program press and release the center button once more. The display will read (-).
ADJUSTING DISPENSE VOLUMES
NOTE: The dispenser should be at operating temperature before setting dispense volumes.
1. Press and hold the hidden programming button, located under the ® next to the BUNN logo on the front of
the dispenser until the 3 LED's begin fl ashing from the left to the right. Release the button.
2. Place an empty graduated container under the dispense nozzle.
3. Press and release the batch size to be set. The LED's will stop fl ashing, and the LED over the button just
pressed will come on solid. Water will begin to dispense into the container.
4. When the desired amount of water is dispensed, press and release the same button. The water will stop
dispensing and the batch size is now set.
5. The LED's will begin fl ashing from left to right again. Repeat steps 2 thru 4 to set up the other batch sizes.
6. To exit the programming set up at any time, press and release the hidden button once. The dispenser is now
ready for use.
39338 100606