New Buck Corporation 1110 Gas Heater User Manual


 
OBSERVED
PROBLEM
1. Igniter button is pressed. No
spark at ODS/Pilot
2. Igniter button is pressed
Spark at ODS/Pilot
No Ignition
POSSIBLE
CAUSE
1. Igniter electrode positioned
incorrectly
2. Igniter electrode broken
3. Igniter electrode not
connected to igniter cable
4. Igniter cable pinched or wet
5. Piezo igniter nut is loose
6. Broken igniter cable
7. Bad piezo igniter
1. Gas supply turned off or
manual shutoff valve is
closed
2. Control knob not in “PILOT”
position
3. Control knob not pressed in
while in “PILOT” position
4. Air in gas lines when installed
5. Depleted gas supply
6. ODS/Pilot is clogged
7. Gas regulator setting is not
correct
SOLUTION
1. Replace igniter
2. Replace igniter
3. Reconnect igniter cable
4. Free igniter cable if pinched
by any metal or tubing. Keep
igniter cable dry.
5. Tighten nut holding piezo
igniter to heater cabinet. Nut
is located inside heater
cabinet at top.
6. Replace igniter cable
7. Replace piezo igniter
1. Turn on gas supply or open
manual shutoff valve
2. Turn control knob to “PILOT”
position
3. Press in control knob while in
“PILOT” position.
4. Continue to hold down control
knob. Repeat igniting
operation until air is removed.
5. Contact local propane gas
company
6. Clean ODS/Pilot or replace
ODS/Pilot assembly
7. Replace gas regulator
32