Bryant TSTAT Thermostat User Manual


 
Fig. 23—Single-Speed Packaged Heat Pump
with 2-Stage Electric Heat (665A, 657A, 664A)
A98506
R
G
Y/Y2
Y1/W2
B
S1
S2
MODEL HP
THERMOSTAT
SPLICE
BOX
VIO
ORN
WHT
RED (TRAN)
BRN
WHT
BRN
See notes 3, 10, 11, and 12
C
O/W2
W/W1
24 VAC COMM
N/A
OUTDOOR
SENSOR
CONNECTION
HEATER
CONTROL BOX
YEL
GRN
RED
RED
PNK
HEAT STAGE 2
COOL/HEAT
STAGE 1
RVS COOLING
N/A
FAN
24 VAC HOT
SUGGESTED DIP
SWITCH SETTINGS
ON
ABCD
OFF OFF OFF OFF
Fig. 21—Single-Speed Packaged Air Conditioner
with 2-Stage Electric Heat
(555A, 557A, 564A)
A98504
COOL STAGE 1
FAN
HEAT STAGE 1
N/A
HEAT STAGE 2
24 VAC HOT
R
G
W/W1
Y1/W2
O/W2
B
S1
S2
MODEL HP
THERMOSTAT
SPLICE
BOX
YEL
GRN
WHT
RED (TRAN)
BRN
WHT
BRN
See notes 2, 10, 11, and 12
C
Y/Y2
24 VAC COMM
N/A
OUTDOOR
SENSOR
CONNECTION
HEATER
CONTROL BOX
RED
RED
VIO
PNK
SUGGESTED DIP
SWITCH SETTINGS
ON
ABCD
OFF OFF ON OFF
Fig. 24—Single-Speed Packaged Heat Pump
with Single-Stage Gas Furnace (658A)
A98507
R
G
W/W1
Y/Y2
B
S1
S2
MODEL HP
THERMOSTAT
SPLICE
BOX
YEL
ORN
BRN
See notes 3, 11, and 12
C
O/W2
Y1/W2
24 VAC COMM
N/A
OUTDOOR
SENSOR
CONNECTION
WHT
GRN
RED
COOL/HEAT
STAGE 1
HEAT STAGE 2
RVS COOLING
N/A
FAN
24 VAC HOT
SUGGESTED DIP
SWITCH SETTINGS
ON
ABCD
OFF OFF OFF OFF
Fig. 22—Single-Speed Packaged Heat Pump
with Single Stage Electric Heat
(655A, 657A, 664A)
A98505
R
G
W/W1
Y/Y2
B
S1
S2
MODEL HP
THERMOSTAT
COOL/HEAT
STAGE 1
HEAT STAGE 2
RVS COOLING
N/A
FAN
24 VAC HOT
SPLICE
BOX
YEL
ORN
WHT
GRN
BRN
WHT
BRN
See notes 3, 11, and 12
C
O/W2
Y1/W2
24 VAC COMM
N/A
OUTDOOR
SENSOR
CONNECTION
HEATER
CONTROL BOX
RED
SUGGESTED DIP
SWITCH SETTINGS
ON
ABCD
OFF OFF OFF OFF
—12—