Bryant T2-PAC Thermostat User Manual


 
5
INSTALLATION
Step 1 — Thermostat Location
S Approximately 5 ft (1.5m) from floor.
S Close to or in a frequently used room, preferably on an inside partition-
ing wall.
S On a section of wall without pipes or duct work.
Thermostat should NOT be mounted
S Close to a window, on an outside wall, or next to a door leading to the
outside.
S Exposed to direct light or heat from the sun, a lamp, fireplace, or other
temperature--radiating objects which could cause a false reading.
S Close to or in direct airflow from supply registers and return --air re-
gisters.
S In areas with poor air circulation, such as behind a door or in an alcove.
Step 2 — Install Thermostat
ELECTRICAL OPERATION HAZA RD
Failure to follow this warning could result in personal injury or
death.
Before installing thermostat, turn off all power to equipment. There
may be more than one power disconnect.
!
WARNING
1. Turn OFF all power to unit.
2. If an existing thermostat is being replaced:
a. Remove existing thermostat from wall.