Bryant A96447 Heating System User Manual


 
—19—
Programming the dehumidification setpoint (optional feature for use with variable speed
equipment):
1. Press the Set Time/Temp and Fan buttons at the same time to enter the humidity programming mode.
2. Press the Set/Time button until the upper setpoint is flashing.
A98176
3. Press the up or down arrows to raise or lower the desired setting. This can be set from 50–90 percent or off.
4. Press the End button at any time to exit the humidity programming function.
Programming your system for the Cool to Dehumidify function:
The dehumidification feature is designed for use with variable speed indoor equipment. However, if you have standard equip-
ment or live or work in a very humid climate, you can choose to run your cooling equipment more often to remove excess mois-
ture from the air. The Cool to Dehumidity feature allows the system to turn on the air conditioning as needed to try to reach the
dehumidification setpoint, while only lowering your indoor temperature 3 degrees. So, if you have set your cooling desired
temperature at 76° and your dehumidification setpoint at 65 percent, the system will turn on the air conditioning to try to reach the
65 percent, allowing the temperature to drop to no less then 73° in your home or business. To activate this function, follow the
steps below:
1. Press the Set Time/Temp and Fan buttons at the same time to enter the humidity programming mode.
2. Press the Set Time/Temp button until the upper setpoint is flashing.
3. Press the up or down arrows to raise or lower the desired setting. This can be set from 50–90 percent or off.
4. Press the Mode button and the COOL icon will be displayed.
5. Press the End button at any time to exit the humidity programming function.
A98177