SPECIFICATIONS
Heating Capacity and Efficiency 30040 30060 42060 48080 60080 42100 60100 60120 60140
Input High
Heat
(BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 140,000
Output High
Heat
(BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 135,000
Efficiency AFUE % (ICS) 95.5 95.5 95.5 95.5 95.5 95.5 95.5 95.5 95.5
Certified Temperature
Rise Range ºF (ºC)
High Heat 40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
45 - 75
(25 - 42)
Airflow Capacity and Blower Data 30040 30060 42060 48080 60080 42100 60100 60120 60140
Certified External Static
Pressure (in. w.c.)
Heating 0.10 0.12 0.12 0.15 0.15 0.20 0.20 0.20 0.20
Cooling 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Airflow Delivery
@ Rated ESP (CFM)
High Heat 820 840 980 1040 1500 1565 1520 2210 2190
Cooling 905 1130 1420 1600 2025 1565 2145 2065 2100
Cooling Capacity (tons)
@ 400, 350 CFM/ton
CFM/ton 2 2.5 3.5 4 5 4 5 5 5
CFM/ton 2.5 3 4 4.5 5.5 4.5 6 6 6
Direct-Drive Motor Type Permanent Split Capacitor (PSC)
Direct-Drive Motor HP 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75
Motor Full Load Amps 6.2 6.2 6.8 7.9 13.8 6.5 13.8 14.1 14.1
RPM Range 500-1150
Speed Selections 4 4 5 5 5 5 5 5 5
Blower Wheel Dia x Width in. 11 x 7 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 10 11 x 11 11 x 11
Air Filtration System Field Supplied
Filter Used for Certified Watt Data
KGAWF1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR
Electrical Data 30040 30060 42060 48080 60080 42100 60100 60120 60140
Input Voltage Volts-Hertz-Phase 115-60-1
Operating Voltage Range Min-Max 104-127
Maximum Input Amps Amps 6.8 7.0 8.4 9.6 14.5 7.6 14.6 14.9 14.9
Unit Ampacity Amps 9.5 9.7 11.5 13.0 19.1 10.4 19.2 19.6 19.6
Minimum Wire Size AWG 14 14 14 14 12 14 12 12 12
Maximum Wire Length Feet 39 38 32 28 30 35 29 29 29
@ Minimum Wire Size (M) (11.9) (11.6) (9.8) (8.5) (9.1) (10.7) (8.8) (8.8) (8.8)
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Amps 15 15 15 15 20 15 20 20 20
Transfomer Capacity (24vac output) 40 VA
External Control Power Available Heating 27.9 VA
Cooling 34.6 VA
Controls 30040 30060 42060 48080 60080 42100 60100 60120 60140
Gas Connection Size 1/2" - NPT
Burners (Monoport) 2 3 3 4 4 5 5 6 7
Gas Valve (Redundant) Manufacturer White Rogers
Minimum Inlet Gas pressure (in. wc) 4.5
Maximum Inlet Gas pressure (in. wc) 13.6
Gas Conversion Kit - Natural to Propane KGANP50011SP
Gas Conversion Kit - Propane to Natural KGAPN42011SP
Manufactured (Mobile) Home Kit KGAMH0601KIT N/A
Ignition Device Silicon Nitride
Limit Control 165 165 180 170 200 180 180 160 155
Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay) 90 seconds
Communication System none
Thermostat Connections Com24V,R,W,G,Y
Accessory Connections EAC (115vac); HUM (24vac)
915SA