SPECIFICATIONS Continued
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
Copper wire must be used from service disconnect to unit.
If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70)
Article 336-26.
Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2 percent.
All motors/compressors contain internal overload protection.
** Time-delay fuse.
†† Use with Low-Ambient Controller.
‡‡ Fan motor with ball bearings required.
UNIT SIZE - SERIES
042-E 048-E/F 060-E
OPERATING WT (Lb) 213 247 287
ELECTRICAL
Unit Volts—Hertz—Phase 208/230—60—1 208/230—60—1 208/230—60—1
Operating Voltage Range* 187—253 187—253 187—253
Compressor— Rated Load Amps 20.0 23.7/21.3 28.8
Locked Rotor Amps 104.0 129.0/137.0 169.0
Condenser Fan Motor—Full Load Amps 1.1 1.4 1.4
Min Unit Ampacity for Wire Sizing 26.1 31.0/28.0 37.4
Min Wire Size (60°C Copper) AWG† 10 8/10 8
Min Wire Size (75°C Copper) AWG† 10 10 8
Max Wire Length (60°C) (Ft)‡ 96 71 104
Max Wire Length (75°C) (Ft)‡ 91 68 99
Max Branch Circuit Fuse Size** 40 50/40 60
COMPRESSOR AND REFRIGERANT
Compressor—Manufacturer & Type Copeland Scroll
Temperature & Current Protection Internal Line Break
Refrigerant—R-22 Amount (Lb) 6.68 6.34 9.25
CONDENSER COIL AND FAN
Coil Face Area (Sq Ft) 15.2 18.3
Fins per In.—Rows—Circuits 25—1—3 25—1—4
Fan Motor—HP, Type, & RPM 1/5 PSC & 825 1/4 PSC & 1100
Volts—Hertz—Phase 208/230—60—1
Condenser Airflow (CFM) 3000 3300
OPTIONAL EQUIPMENT
Support Feet Kit KSASF0101AAA
Coastal Filter KAACF0201MED
Time-Delay Relay KAATD0101TDR
Cycle Protector KSACY0101AAA Standard
Crankcase Heater KAACH1201AAA
Start Assist—Capacitor/Relay Type KSAHS1501AAA KSAHS1601AAA
Start Assist—PTC Type KAACS0201PTC
TXV Kit (RPB) KAATX0501RPB KAATX0601RPB KAATX0701RPB
TXV Kits (Hard Shutoff) KSATX0601HSO KSATX0701HSO
Low-Pressure Switch KAALP0101LPS
High-Pressure Switch KSAHI0101HPS
Filter Drier P502-8163S (RCD)
Evaporator Freeze Thermostat†† KAAFT0101AAA
Liquid-Line Solenoid Valve KAALS0101LLS
Winter Start Control†† KAAWS0101AAA
Low-Ambient Kit KSALA0201R22
Low-Ambient Controller P251-0083 (RCD)
MotorMaster® Control‡‡ 32LT660004 (RCD)
Ball Bearing Fan Motor HC38GE231 (RCD) HC40GE232 (RCD)
Thermostat, Auto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Builder’s Thermostat, Manual
Changeover, Non-Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B
Thermidistat™ Control—Programmable/
Non-Programmable Thermostat with
Humidity Control TSTATBBPRH01-B
Outdoor Air Temperature Sensor TSTATXXSEN01-B
Backplate for Non-Programmable
Thermostat TSTATXXNBP01
Backplate for Builder’s Thermostat TSTATXXBBP01
Backplate for Programmable Thermostat TSTATXXPBP01
Thermostat Conversion Kit (4 to 5 wire)
— 10 Pack TSTATXXCNV10