Bryant 594D Air Conditioner User Manual


 
—18—
DETAILED COOLING CAPACITIES* Continued
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI Standard 210/240-94. If additional tubing length and/or indoor
unit is located above outdoor unit, a slight variation in capacity may occur.
Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.
** Unit kw is total of indoor and outdoor unit kilowatts.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
85 95 105 115 125
CFM EWB
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
594D060-E Outdoor Section With CC5A/CD5AW060 Indoor Section
1750
72 63.4 31.4 5.42 61.0 30.4 5.88 58.2 29.4 6.35 54.9 28.2 6.7 50.9 26.8 7.13
67 57.8 39.6 5.36 55.4 38.6 5.79 52.5 37.5 6.21 49.0 36.1 6.5 44.8 34.4 6.76
62 52.4 47.6 5.28 49.9 46.4 5.68 46.9 44.8 6.02 43.4 42.8 6.2 39.7 39.7 6.37
57 50.2 50.2 5.20 48.2 48.2 5.59 45.9 45.9 5.93 43.2 43.2 6.2 40.1 40.1 6.37
2000
72 64.7 32.8 5.44 62.1 31.8 5.91 59.3 30.8 6.38 56.0 29.7 6.8 52.1 28.3 7.22
67 59.0 42.0 5.38 56.5 41.0 5.82 53.6 39.9 6.26 50.2 38.5 6.6 46.1 37.0 6.89
62 53.6 50.7 5.31 51.1 49.4 5.72 48.3 47.6 6.10 45.1 45.1 6.3 41.9 41.9 6.59
57 52.2 52.2 5.24 50.3 50.3 5.65 48.0 48.0 6.03 45.4 45.4 6.3 42.3 42.3 6.57
2250
72 65.7 34.1 5.34 62.9 33.1 5.93 60.1 32.1 6.42 56.9 31.0 6.8 53.0 29.7 7.30
67 60.0 44.4 5.28 57.4 43.3 5.86 54.5 42.2 6.30 51.2 40.9 6.7 47.0 39.3 7.00
62 54.6 53.4 5.34 52.2 51.8 5.77 49.6 49.6 6.17 46.9 46.9 6.5 43.7 43.7 6.76
57 54.0 54.0 5.27 52.0 52.0 5.69 49.8 49.8 6.10 47.2 47.2 6.4 44.0 44.0 6.74
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 060 0.96 0.98 FC4BNB 070 1.02 1.02
CC5A/CD5AW 060 1.00 1.00 FC4BN(F,B) 060 1.01 1.04
CE3AA 060 1.00 1.00 FG3AAA 060 0.99 1.00
CK5A/CK5BA 060 0.96 0.98 FK4CNB 006 1.02 0.97
CK5A/CK5BX 060 1.00 1.00
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
F(A,B)4AN(F,B,C) 060 1.01 1.04 CC5A/CD5AW 060 1.00 0.94
FB4ANB 070 1.02 1.02 CK5A/CK5BW 060 1.00 0.94