Bryant 588A Air Conditioner User Manual


 
DRY COIL AIR DELIVERY* VERTICAL DISCHARGE
(Deduct 10% for 208 v)
UNIT
SIZE
588A
MOTOR
SPEED
230 AND 460 VOLT VERTICAL DISCHARGE
External Static Pressure (in. wg)
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
018
Low
Watts 295 251 223 201 176 149 124
Cfm 821 817 753 665 536 343 164
High
Watts 401 376 346 322 294 272 250 229 219
Cfm 1334 1253 1128 996 816 658 461 246 167
024,
030
Low
Watts 285 284 282 278 274 270 261 251 244 230
Cfm 798 761 727 682 634 581 525 450 371 304
Med
Watts 378 371 368 362 357 343 332 315 301 283
Cfm 1011 982 948 906 858 771 703 597 492 387
High
Watts 520 511 487 472 451 431 411 385 362 341
Cfm 1342 1289 1237 1181 1106 1007 892 745 610 471
036
Low
Watts 460 439 423 898 379 349 322 297 270 246
Cfm 1191 1136 1081 1005 907 795 687 579 471 349
Med
Watts 511 492 470 450 420 392 364 332 308 275
Cfm 1316 1244 1178 1104 1005 891 784 657 535 389
High
Watts 655 631 603 584 552 522 492 459 433 398
Cfm 1541 1458 1367 1292 1178 1053 920 806 662 509
042
Low
Watts 637 612 587 560 536 493 455
Cfm 1500 1450 1405 1350 1290 1200 1105
High
Watts 790 750 700 699 639 608 574 547
Cfm 1750 1625 1604 1509 1421 1323 1221 1094
048
Low
Watts 847 784 746 708 646 609 563 516
Cfm 1995 1901 1822 1730 1580 1477 1319 1178
High
Watts 909 852 820 801 751 687 639
Cfm 2018 1896 1814 1729 1582 1380 1220
060
Low
Watts 970 952 928 905 880 847 804 760
Cfm 2075 2054 2024 1994 1945 1890 1830 1762
Med
Watts 1291 1247 1195 1076 1025 970 921 833 810
Cfm 2395 2348 2291 2164 2099 2022 1950 1827 1804
High
Watts 1490 1400 1312 1270 1219 1161 1104 1045 985 930
Cfm 2530 2475 2420 2355 2289 2223 2150 2079 2008 1932
*Air delivery values are based on operating voltage of 230 v or 460 v, dry coil, without filter. De-
duct wet coil and filter pressure drops to obtain external static pressure available for ducting.
NOTES:
1. Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of
rated cooling capacity. Evaporator coil frosting may occur at airflows below this point.
2. Dashes indicate portions of table that are beyond the blower motor capacity or are not
recommended.
18