Bryant 581A Gas Heater User Manual


 
14
**ARI* CAPACITY RATINGS — 581C024-060
LEGEND
*Air-Conditioning & Refrigeration Institute.
**ARI does not require EER ratings for unit with capacity below 65,000 Btuh. For
these units, the EER rating at ARI standard conditions is provided for informa-
tion only.
NOTES:
1. Rated in accordance with ARI Standard 210-94 or 360-93.
2. Ratings are net values, reflecting the effects of circulating fan heat.
3. Ratings are based on:
Cooling Standard: 80 F db, 67 wb indoor entering-air temperature and 95 F
db outdoor entering-air temperature.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F
db outdoor entering-air temperature.
4. All 581C024-060 units are in compliance with ASHRAE 90.1 2001, 2004
Energy Standard for minimum SEER and EER requirements. Refer to state
and local codes or visit the following website: http://bcap-energy.org
to
determine if compliance with this standard pertains to a given geographical
area of the United States.
HEATING CAPACITIES AND EFFICIENCIES — 581C024-060
208/230-1-60 — SINGLE-STAGE GAS HEAT
208/230-1-60 — SINGLE-STAGE GAS HEAT — LOW NOx
AFUE — Annual Fuel Utilization Efficiency
NOTE: Capacities for stainless steel heat exchanger units (S/R/T) are the same
as standard units (D/E/F).
UNIT
581C
NOMINAL
TONS
COOLING
(Btuh)
TOTAL
kW
SEER EER
SOUND RATING
(decibels)
024 2 24,000 3.2 14.1 12.0** 76
036 3 36,200 4.1 14.0 11.8** 76
048 4 46,000 5.5 14.0 11.7** 76
060 5 59,000 6.7 14.0 11.9 80
EER Energy Efficiency Ratio
SEER Seasonal Energy Efficiency Ratio
UNIT INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE MINIMUM HEATING EFFICIENCY
581C 1st Stage
2nd
Stage
1st Stage 2nd Stage RISE (°F) AIRFLOW (CFM) AFUE (%)
Steady State
(%)
024050 50,000 40,500 25-65 575 81.00 81
036072 72,000 59,040 25-55 1004 82.80 82
036115 115,000 92,000 55-85 1002 80.00 80
048072 72,000 58,000 25-55 1004 82.80 82
048115 115,000 92,000 35-65 1320 81.00 81
048150 150,000 118,000 50-80 1396 80.40 80
060072 72,000 58,000 25-55 1004 82.80 82
060115 115,000 92,000 35-65 1327 81.00 81
060150 150,000 118,000 50-80 1314 80.40 80
UNIT INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE MINIMUM HEATING EFFICIENCY
581C 1st Stage 2nd Stage 1st Stage 2nd Stage RISE (°F) AIRFLOW (CFM) AFUE (%) Steady State (%)
024050N 50,000 40,500 25-65 575 81.00 81
036060N 60,000 50,000 20-50 930 80.20 81
036090N 90,000 74,000 30-60 1150 81.00 81
048060N 60,000 50,000 20-50 930 80.20 81
048090N 90,000 74,000 30-60 1150 81.00 81
048120N 120,000 101,000 40-70 1340 80.70 82
060060N 60,000 50,000 20-50 930 80.20 81
060090N 90,000 74,000 30-60 1150 81.00 81
060120N 120,000 101,000 40-70 1340 80.70 82