SYSTEM DESIGN SUMMARY
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Maximum elevation of indoor coil above or below base of outdoor unit without additional consideration is: Indoor coil above = 20 ft,
indoor coil below = 20 ft. Consult Application Guidelines and Service ManualAir Conditioners and Heat Pumps Using Puron®
Refrigerant prior to application if elevations are exceeded.
6. For interconnecting refrigerant tube lengths greater than 50 ft and/or 20 ft vertical differential, consult the Application Guideline and
Service ManualAir Conditioners and Heat Pumps Using Puron® Refrigerant Application Guideline and Service ManualAir Con-
ditioners and Heat Pumps Using Puron® Refrigerant available from equipment distributor.
7. If any refrigerant tubing is buried, provide a 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36
in. may be buried without further consideration. Do not bury lines over 36 in.
8. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
9. Do not apply capillary tube indoor coils to these units.
10. Factory-supplied lter drier must be installed. This must be replaced each time the refrigeration system is opened for service.
11. Do not deviate from factory specied TXVs and Liquid Line Solenoids.
CONDENSER ONLY RATINGS* Continued
* ARI listing applies only to systems shown in Ratings and Performance table.
kW Outdoor Unit Kilowatts only.
SDT Saturated Temperature Leaving Compressor (°F)
SST Saturated Temperature Entering Compressor (°F)
TCG Gross Cooling Capacity (1000 Btuh).
SST
°F
CONDENSER ENTERING AIR TEMPERATURES °F
55 65 75 85 95 105 115 125
552AN048-F
30
TCG
SDT
KW
43.2
77.6
2.18
40.8
87.0
2.48
38.5
96.5
2.82
36.2
106.
3.20
33.8
115.
3.61
31.4
125.
4.08
28.9
134.
4.58
26.2
143.
5.14
35
TCG
SDT
KW
47.2
79.4
2.23
44.7
88.7
2.53
42.2
98.2
2.86
39.6
108.
3.25
37.0
117.
3.66
34.4
126.
4.12
31.6
136.
4.63
28.7
145.
5.19
40
TCG
SDT
KW
51.5
81.4
2.28
48.8
90.6
2.58
46.0
99.9
2.92
43.3
109.
3.30
40.4
119.
3.72
37.6
128.
4.18
34.5
137.
4.68
31.3
146.
5.23
45
TCG
SDT
KW
56.0
83.5
2.34
53.1
92.6
2.64
50.1
102.
2.97
47.1
111.
3.35
44.0
120.
3.78
40.9
130.
4.24
37.6
139.
4.74
34.0
147.
5.29
50
TCG
SDT
KW
60.8
85.7
2.40
57.7
94.7
2.70
54.4
104.
3.04
51.2
113.
3.42
47.8
122.
3.84
44.4
131.
4.30
40.8
140.
4.80
36.9
149.
5.34
55
TCG
SDT
KW
65.8
88.1
2.47
62.5
96.9
2.77
59.1
106.
3.11
55.5
115.
3.49
51.8
124.
3.91
48.0
133.
4.38
44.2
142.
4.87
39.9
150.
5.40
552AN060-F
30
TCG
SDT
KW
53.4
77.9
2.79
50.5
87.5
3.18
47.6
97.1
3.61
44.7
107.
4.10
41.8
116.
4.64
38.8
126.
5.23
35.7
135.
5.88
32.5
144.
6.60
35
TCG
SDT
KW
58.4
79.8
2.85
55.2
89.2
3.24
52.1
98.8
3.67
48.9
108.
4.16
45.7
118.
4.71
42.5
127.
5.30
39.1
137.
5.95
35.5
146.
6.66
40
TCG
SDT
KW
63.7
81.8
2.92
60.3
91.1
3.30
56.9
101.
3.74
53.4
110.
4.23
49.9
120.
4.78
46.4
129.
5.37
42.7
138.
6.02
38.7
147.
6.72
45
TCG
SDT
KW
69.3
83.9
2.99
65.6
93.1
3.37
62.0
102.
3.81
58.2
112.
4.30
54.4
121.
4.85
50.5
131.
5.45
46.4
140.
6.10
42.1
149.
6.80
50
TCG
SDT
KW
75.2
86.1
3.06
71.3
95.3
3.45
67.3
105.
3.89
63.3
114.
4.38
59.1
123.
4.93
54.8
132.
5.54
50.4
141.
6.18
45.6
150.
6.88
55
TCG
SDT
KW
81.4
88.5
3.15
77.2
97.5
3.54
72.9
107.
3.98
68.5
116.
4.47
64.0
125.
5.02
59.3
134.
5.63
54.5
143.
6.28
49.2
152.
6.96