Bryant 552A Air Conditioner User Manual


 
31
DETAILED COOLING CAPACITIES* Continued
See notes on page 32.
EVAP
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh
Total
Sys
kW**
Capacity
MBtuh
Total
Sys
kW**
Capacity
MBtuh
Total
Sys
kW**
Capacity
MBtuh
Total
Sys
kW**
Capacity
MBtuh
Total
Sys
kW**
Capacity
MBtuh
Total
Sys
kW**Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens
552AN048-F Outdoor Section With CK5A/CK5BA060 Indoor Section continued
1400
72 53.9 26.9 3.58 51.7 26.2 3.98 49.2 25.4 4.42 46.4 24.5 4.90 43.6 23.6 5.45 40.3 22.5 6.07
67 50.4 35.1 3.52 48.0 34.2 3.90 45.4 33.2 4.34 42.8 32.3 4.82 39.5 31.1 5.35 34.7 29.2 5.90
63†† 47.3 34.5 3.48 44.9 33.5 3.85 42.4 32.4 4.28 38.8 30.9 4.73 34.8 29.2 5.22 30.0 27.2 5.75
62 46.7 43.1 3.46 44.4 42.0 3.84 41.7 40.7 4.26 39.0 39.0 4.73 36.0 36.0 5.25 32.3 32.3 5.82
57 45.4 45.4 3.44 42.8 42.8 3.82 40.1 40.1 4.23 38.4 38.4 4.72 35.5 35.5 5.24 32.3 32.3 5.83
1600
72 54.1 27.7 3.66 52.0 27.0 4.06 49.6 26.4 4.50 47.1 25.7 5.01 44.2 24.9 5.56 40.6 23.8 6.18
67 50.8 36.8 3.60 48.6 36.2 3.99 46.0 35.4 4.43 43.4 34.5 4.92 40.1 33.4 5.45 35.2 31.5 6.01
63†† 47.9 36.4 3.55 45.7 35.6 3.95 43.1 34.5 4.37 39.3 33.0 4.82 35.2 31.3 5.31 30.3 29.2 5.84
62 47.7 46.2 3.56 45.4 45.0 3.94 43.0 43.0 4.37 40.4 40.4 4.85 37.2 37.2 5.37 33.3 33.3 5.95
57 47.4 47.4 3.55 44.9 44.9 3.93 43.3 43.3 4.38 41.0 41.0 4.86 37.8 37.8 5.38 34.1 34.1 5.96
1800
72 54.7 28.7 3.75 52.6 28.1 4.15 50.3 27.7 4.60 47.4 26.8 5.09 44.4 26.1 5.64 40.9 25.0 6.28
67 51.3 38.6 3.69 49.1 38.2 4.08 46.5 37.4 4.51 43.8 36.6 5.00 40.6 35.5 5.55 35.7 33.7 6.11
63†† 48.4 38.2 3.64 46.2 37.6 4.03 43.6 36.6 4.46 40.1 35.1 4.92 35.6 33.2 5.40 30.8 30.8 5.94
62 48.7 48.6 3.65 46.4 46.4 4.03 44.4 44.4 4.47 42.2 42.2 4.97 38.5 38.5 5.49 34.4 34.4 6.07
57 48.5 48.5 3.64 46.4 46.4 4.03 44.3 44.3 4.47 42.2 42.2 4.97 39.6 39.6 5.51 35.2 35.2 6.09
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
CK5A/CK5BT 048 0.97 0.94 CK5A/CK5BA 048 0.97 0.97
060 0.98 0.92 CK5PA 048 0.97 0.97
CK5A/CK5BW 048 0.97 0.94
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CK5A/CK5BX 060 0.99 0.91 CC5A/CD5AW 060 0.99 0.98
CK5PA 048 0.97 0.93 CK3BA 048 0.97 0.98
060 0.98 0.92 060 0.98 0.97
CK5PT 048 0.97 0.93 CK5A/CK5BA 060 0.98 0.97
060 0.98 0.92 CK5A/CK5BX 060 1.00 0.97
CK5PW 048 0.97 0.93 CK5PA 060 0.98 0.97
CK5PX 060 0.99 0.91 CK5PX 060 1.00 0.97
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE COILS + 355MAV060100 VARIABLE SPEED FURNACE
CC5A/CD5AA 060 0.98 0.93 CC5A/CD5AA 060 0.97 0.95
CC5A/CD5AC 048 0.96 0.93 CC5A/CD5AC 048 0.96 0.96
CC5A/CD5AW 048 0.97 0.92 CC5A/CD5AW 060 0.99 0.95
060 0.99 0.92 CD5AA 048 0.97 0.95
CD5AA 048 0.97 0.92 CK3BA 048 0.97 0.95
CE3AA 048 0.97 0.93 060 0.98 0.97
060 0.98 0.91 CK5A/CK5BA 048 0.97 0.95
CK3BA 048 0.97 0.93 060 0.98 0.94
060 0.98 0.91 CK5A/CK5BX 060 1.00 0.95
CK5A/CK5BA 048 0.97 0.93 CK5PA 048 0.97 0.95
060 0.98 0.91 060 0.98 0.94
CK5A/CK5BT 048 0.97 0.93 CK5PX 060 1.00 0.95
060 0.98 0.91
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CK5A/CK5BW 048 0.97 0.93 CC5A/CD5AA 060 0.97 0.95
CK5A/CK5BX 060 0.99 0.91 CC5A/CD5AW 048 0.98 0.96
CK5PA 048 0.97 0.93 060 0.99 0.94
060 0.98 0.91 CK3BA 060 0.98 0.96
CK5PT 048 0.97 0.93 CK5A/CK5BA 060 0.98 0.94
060 0.98 0.91 CK5A/CK5BW 048 0.97 0.94
CK5PW 048 0.97 0.93 CK5A/CK5BX 060 1.00 0.94
CK5PX 060 0.99 0.91 CK5PA 060 0.98 0.94
COILS + 355MAV042080 VARIABLE SPEED FURNACE CK5PW 048 0.97 0.94
CD5AA 048 0.97 0.97 CK5PX 060 1.00 0.94
CK3BA 048 0.97 0.97 ——