CK5PT042 40,500 TDR&TXV 13.00 11.30
CK5PT048 40,500 TDR&TXV 13.20 11.55
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 40,500 TDR 13.20 13.20 11.50
CC5A/CD5AC048 40,000 TDR 13.20 13.20 11.55
CD5AA048 40,500 TDR 13.50 13.50 11.75
CE3AA042 41,000 TDR 13.20 13.20 11.60
CE3AA048 41,000 TDR 13.50 13.50 11.65
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 40,500 TDR 13.20 13.20 11.50
CC5A/CD5AC048 40,000 TDR 13.20 13.20 11.55
CD5AA048 40,500 TDR 13.50 13.50 11.75
CE3AA042 41,000 TDR 13.20 13.20 11.60
CE3AA048 41,000 TDR 13.50 13.50 11.65
CK3BA042 40,500 TDR 13.00 13.00 11.55
CK3BA048 40,500 TDR 13.50 13.50 11.80
CK5A/CK5BA042 40,500 TDR 13.00 13.00 11.55
CK5A/CK5BA048 40,500 TDR 13.50 13.50 11.80
CK5A/CK5BT042 40,500 TDR 13.00 13.00 11.55
CK5A/CK5BT048 40,500 TDR 13.50 13.50 11.80
CK5PA042 40,500 TDR&TXV 13.00 11.55
CK5PA048 40,500 TDR&TXV 13.50 11.80
CK5PT042 40,500 TDR&TXV 13.00 11.55
CK5PT048 40,500 TDR&TXV 13.50 11.80
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 40,500 TDR 13.20 13.20 11.50
CC5A/CD5AW048 40,500 TDR 13.50 13.50 11.75
CE3AA042 41,000 TDR 13.20 13.20 11.60
CE3AA048 41,000 TDR 13.50 13.50 11.65
CK3BA042 40,500 TDR 13.00 13.00 11.65
CK3BA048 40,500 TDR 13.50 13.50 11.85
CK5A/CK5BA042 40,500 TDR 13.00 13.00 11.65
CK5A/CK5BT042 40,500 TDR 13.00 13.00 11.65
CK5A/CK5BW048 40,500 TDR 13.50 13.50 11.85
CK5PA042 40,500 TDR&TXV 13.00 11.65
CK5PT042 40,500 TDR&TXV 13.00 11.65
CK5PW048 40,500 TDR&TXV 13.50 11.85
048-F
*CC5A/CD5AA060 46,500 NONE 13.00 13.00 11.50
CC5A/CD5AC048 45,000 NONE 12.50 12.50 11.35
CC5A/CD5AW048 46,000 NONE 13.00 13.00 11.50
CC5A/CD5AW060 47,000 NONE 13.00 13.00 11.80
CD5AA048 46,000 NONE 13.00 13.00 11.50
CD5PX060 47,500 TXV 13.50 11.90
CE3AA048 46,500 NONE 13.00 13.00 11.65
CE3AA060 47,000 NONE 13.00 13.00 11.85
CF5AA048 46,000 NONE 12.50 12.50 11.55
CK3BA048 46,000 NONE 13.00 13.00 11.55
CK3BA060 46,500 NONE 13.00 13.00 11.65
CK5A/CK5BA048 46,000 NONE 13.00 13.00 11.55
CK5A/CK5BA060 46,500 NONE 13.00 13.00 11.65
CK5A/CK5BT048 46,000 NONE 13.00 13.00 11.55
CK5A/CK5BT060 46,500 NONE 13.00 13.00 11.65
CK5A/CK5BW048 46,000 NONE 13.00 13.00 11.55
CK5A/CK5BX060 47,000 NONE 13.00 13.00 11.90
CK5PA048 46,000 TXV 13.00 11.55
CK5PA060 46,500 TXV 13.00 11.65
CK5PT048 46,000 TXV 13.00 11.55
CK5PT060 46,500 TXV 13.00 11.65
CK5PW048 46,000 TXV 13.00 11.55
CK5PX060 47,000 TXV 13.00 11.90
F(A,B)4(A,B)N(F,B,C)048 46,000 TDR 12.20 12.20 11.50
F(A,B)4(A,B)N(F,B,C)060 47,000 TDR 12.50 12.50 11.55
FB4(A,B)NB070 47,500 TDR 13.00 13.00 12.00
FE4ANB006 47,500 TDR&TXV 14.00 13.15
FE4ANF005 47,000 TDR&TXV 13.80 12.40
FG3AAA048 46,000 NONE 12.20 12.20 11.50
FG3AAA060 46,500 NONE 12.50 12.50 11.65
FK4(C,D)NB006 47,500 TDR&TXV 14.00 13.15
FK4(C,D)NF005 47,000 TDR&TXV 13.80 12.40
FV4(A,B)NB006 47,500 TDR&TXV 14.00 13.15
FV4(A,B)NF005 47,000 TDR&TXV 13.80 12.40
FX4(A,B)NB060 47,000 TDR&TXV 12.50 11.50
FX4(A,B)NF048 46,000 TDR&TXV 12.20 11.50
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AC048 45,000 TDR 13.00 13.00 11.80
CD5AA048 46,000 TDR 13.50 13.50 11.95
CE3AA048 46,500 TDR 13.50 13.50 11.95
CE3AA060 47,000 TDR 13.50 13.50 12.25
CK3BA048 46,000 TDR 13.50 13.50 11.95
CK5A/CK5BA048 46,000 TDR 13.50 13.50 11.95
CK5A/CK5BT048 46,000 TDR 13.50 13.50 11.95
CK5PA048 46,000 TDR&TXV 13.50 11.90
CK5PT048 46,000 TDR&TXV 13.50 11.90