Bryant 353AAV Furnace User Manual


 
4
PHYSICAL DATA
**Note: 060--120 Sizes are phasing out.**
UNIT SIZE 036040 036060 036080 048080 060100 060120
SHIPPING WEIGHT LB. (KG) 175 (47) 182 (57) 198 (64) 205 (69) 232 261 (74)
LIMIT CONTROL SPST
HEATING BLOWER CONTROL
(Off Delay)
Solid---State Time Operation
BURNERS (Monoport) 2 3 4 4 5 6
GAS CONNECTION SIZE 1/2---in. NPT
GAS VALVE(Redundant)
Manufacturer
White --- Rodgers
Minimum Inlet Pressure
(in. wc)
4.5 (Natural Gas)
Maximum Inlet Pressure
(in. wc)
13.6 (Natural Gas)
IGNITION DEVICE Hot Surface
DIRECT---DRIVE MOTOR
( EC M X --- 13 )
1/2 1/2 1/2 3/4 1 1
MOTOR FULL LOAD AMPS 6.8 6.8 6.8 8.4 10.9 10.9
R PM ( No mi na l) --- S PE ED S 1050---5
BLOWER WHEEL DIAMETER X
W ID TH --- I N (m m)
10 X 7
(254 X 178)
10 X 7
(254 X 178)
10 X 7
(254 X 178)
11 X 8
(279 X 203)
11 X 10
(279 X 254)
11 X 10
(279 X 254)
F ILT ER S IZ E (W as ha bl e) ---
IN (mm)
(1) 16 X 25 X 3/4
(406 X 635 X 19)
(1) 20 X 25 X 3/4
(508 X 635 X 19)
(1) 24 X 25 X 3/4
(610 X 635 X 19)
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
CERTIFIED
Always Ask For
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
353AAV