Bryant 331JAV Furnace User Manual


 
—4—
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: PDS 331J.60.3
© 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 5233-103 10-99
AIR DELIVERY— CFM (With Filter)
A97620
UNIT
SIZE
BLOWER
MOTOR HP SPEED
EXTERNAL STATIC PRESSURE (IN. WC)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
036060 1/3 PSC
High
Med-High
Med
Med-Low
Low
1435
1195
1030
900
705
1385
1165
1020
890
700
1320
1145
1010
875
690
1265
1105
985
855
675
1195
1070
955
835
655
1145
1015
915
795
625
1080
955
860
755
580
1000
885
790
690
525
048080 1/2 PSC
High
Med-High
Med
Med-Low
Low
1855
1595
1355
1170
880
1765
1570
1345
1170
865
1710
1530
1305
1140
855
1665
1485
1270
1110
830
1580
1410
1220
1075
805
1570
1355
1170
1025
755
1410
1280
1110
965
720
1310
1200
1025
890
655
060100 3/4 PSC
High
Med-High
Med
Med-Low
Low
2235
1995
1735
1510
1145
2185
1970
1735
1500
1140
2110
1915
1675
1485
1125
2030
1845
1625
1455
1115
1950
1765
1565
1400
1100
1835
1680
1480
1320
1085
1700
1545
1370
1230
1045
1540
1415
1265
1130
990
322567-101 REV. E (LIT)
MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION
INSTALLATION
This unit is certified for downflow installation only. See Installation Manual for
important installation instructions.
This forced air furnace is equipped for
use with natural gas at altitudes 0 -
10,000 ft
(0-3,050m).
An accessory kit, supplied by the
manufacturer, shall be used to convert to
propane gas use or may be required for
some natural gas applications.
This furnace is for indoor installation in
a building constructed on site.
This furnace may be installed on
combustible flooring in alcove or closet at
minimum clearance from combustible
material.
This furnace may be used with a Type
B-1 Vent and may be vented in common
with other gas-fired appliances.
Clearance in inches.
BOTTOM
##
1" #
0"
1"
1"
30"
MIN
S
I
D
E
F
R
O
N
T
B
C
K
A
S
E
R
V
I
E
C
F
R
O
N
T
S
I
E
U
F
R
N
A
C
E
#
Ø
TOP / PLENUM
D
1"
Ø
For installation on non-combustible
floors only. For installation on
combustible flooring only when
installed on special base, Part No.
KGASB0201ALL, Coil Assembly,
Part No. CD5 or CK5, or Coil
Casing, Part No. KCAKC.
For furnaces wider than 14.25
inches (362mm) may be 0 inches.
18 inches front clearance required
for alcove.
For single wall vent type 6 inches.
#
##
Vent Clearance to combustibles:
For Single Wall vents 6 inches (6 po).
For Type B-1 vent type 1 inch (1 po).
This furnace is approved for DOWNFLOW installations only.