START--UP AND OPERATION
Step 1 Checking Air Purifier Operation
ELECTRICAL SHOCK AND HIGH VOLTAGE
HAZARD
Failure to follow this w arning could r esult in personal injury
or death.
Before installing o r servicing system, always turn off main
power to system. There may be more than one (1) disconnect
switch.
!
WARNING
a. Attach the Perfect Airt Air Purifier door to the cabinet.
A magnet in the door (see Fig. 8) is used to activate a safe-
ty switch in the power supply when the door is installed.
The power supply will not energize the air purifier unless
the safety switch is activated.
b. Turn the HVAC system power on and adjust the thermo-
stat or Evolutiont System Control to activate the system
fan.
c. Turn the Perfect Airt Air Purifier power switch t o on
position.
d. The power indicator light above the Air Purifier power
switch should illuminate (see Fig. 13).
e. Check to ensure the light goes off when the Perfect Airt
Air Purifier power switch is set to off, when the blower
goes off, or when the HVAC system power is turned off.
NOTE: Upon power--up, the light will come on for
approximately 5 seconds and if no flow is detected, it will go off.
If no air purifier cartridge is detected, the flow sensor will detect
this and turn off after approximately 7 seconds.
Step 2 Evolution Control
a. When the Perfect Airt Air Purifieris used with anEvolu-
tion Control, the Evolution Control can be configured to
remind the homeowner when it is time to change the Per-
fect Airt Air Purifier cartridge. This maintenance re-
minder can be based on either the TrueSenset dirty filter
algorithm ortime. The installer shoulduse their discretion
to select the most appropriate option based on the initial
system static pressure.
Step 3 Maximizing Performance
a. Maximum air purification performance is obtained when
the furnace blower is set for continuous operation on the
thermostat or Evolution Control.
Door Switch Magnet
A06369
Fig. 12 --- Door Switch Magnet
Power Indicator
A06370
Fig. 13 --- Power Indicator
MAINTENANCE
The Perfect Air t Air Purifier is designed to require minimal
maintenance. Maintenance is limited to the replacement of the
air purification cartridge and inspection/brush cleaning of the
ionization array. Frequency of air purifier cartridge replacement
and cleaning of the ionization array may vary depending on
ductwork design and local environmental conditions.
To replace the air purifier cartridge, complete the following
steps:
Step 1 Turn the heating and cooling system power off.
ELECTRICAL SHOCK AND HIGH VOLTAGE
HAZARD
Failure to follow this w arning could r esult in personal injury
or death.
Before installing o r servicing system, always turn off main
power to system. There may be more than one (1) disconnect
switch.
!
WARNING
Step 2 Turn the Perfect Airt Air Purifier switch to the off
position.
Step 3 Remove the Perfect Airt Air Purifier door.
Step 4 Slide out the old air purifier cartridge and discard.
Step 5 Install the new air purifier cartridge.
NOTE: Make sure that the arrows on the air purifier cartridge
point toward the fan coil. This should be in the same
direction as airflow.
Step 6 Replace the Perfect Airt Air Purifier door.
Step 7 Turn the Perfect Airt Air Purifier switch to the on
position.
Step 8 Turn heating and cooling system power on.
GAPAB