8. ELECTRIC MECHANISM
KE-430B, 430C series
153
<Memory switches 30 - 4F>
30 to 4F are set by entering two-digit values.
These values are incremented using the P2 switch, and decremented using the P4 switch.
Switch
Possible
setting range
Units
Initial
value
Explanation
0 - 30
<KE-430*, 431*, 432*, 433B, BE-438*>
Limits the maximum area in the horizontal direction (X).
memo-30
0 - 99
mm ***
<KE-434*, 435*, 484C>
Limits the maximum area in the horizontal direction (X).
0 - 30
<KE-430*, 431*, 432*, 433B, BE-438*>
Limits the maximum area in the vertical direction (Y).
memo-31
0 - 60
mm ***
<KE-434*, 435*, 484C>
Limits the maximum area in the vertical direction (Y).
12 - 27 27
<KE-430*, 431*, 432*>
Changes the maximum sewing speed.
12 - 25 25
<KE-433B, 434*, 435*, BE-438*>
Changes the maximum sewing speed.
memo-32
12 - 22
100rpm
22
<KE-484C>
Changes the maximum sewing speed.
1 - 10 5
<KE-430*, 431*, 432*, 433B, 434*, 435*, 484C>
Changes the feed timing
1 (Fast) 5 (Standard) 10 (Slow)
memo-33
1 - 15
7.5
10
<BE-438*>
Changes the feed timing
1 (Fast) 10 (Standard) 15 (Slow)
0
<KE-430*, 431*, 432*, 433B, 434*, 435*, 484C>
The (setting value + 1) number of stitches are sewn at
the speed set by memo-35 at the sewing start. (No
low-speed sewing if set to 0.)
memo-34 0 - 5 Stitch
1
<BE-438*>
The (setting value + 1) number of stitches are sewn at
the speed set by memo-35 at the sewing start. (No
low-speed sewing if set to 0.)
memo-35 3 - 9
100rpm
4
Changes the sewing start speed for the number of
stitches specified by memo-34.
memo-36 - - - -
memo-37 1 - 20
7.5
10
Changes the feed timing one stitch before the sewing
end.
1 (Fast) 10 (Standard) 20 (Slow)
memo-38 1 - 20
7.5
10
Changes the feed timing two stitches before the sewing
end.
10
<KE-430*, 431*, 432*, 433B, 434*, 435*, 484C>
Changes the feed timing for the third stitch at the
sewing start. 1 (Fast) 10 (Standard) 20 (Slow)
memo-39 1 - 20
7.5
1
<BE-438*>
Changes the feed timing for the third stitch at the
sewing start. 1 (Fast) 10 (Standard) 20 (Slow)
*** Default values for each model setting
Model Default value for memo-30 Default value for memo-31
KE-430* 30 26
KE-431* 30 10
KE-432* 12 3
KE-433B 30 30
KE-434*, 435*,
484C
99
(If the value is set to 99, the maximum
length allowed will be 100 mm)
60
BE-438* 7 (Limited to 6.4 mm) 7 (Limited to 6.4 mm)