Brother 435B Sewing Machine User Manual


 
8. ELECTRIC MECHANISM
KE-430B, 430C series
151
<Memory switches 00 - 0F>
Initial value
Switch Motion when set to ON
Solenoid
Pneumatic
memo-00
At the end of sewing, the feed plate will be returned to the sewing start point via
mechanical home position.
-- --
memo-01
Work clamp (button clamp) will move to the sewing start point, and then will be
lifted.
(For models with solenoid specifications other than the KE-434*, the work
clamp rises at the final stitch to enable quick taking out of the workpieces.)
*1 ON
memo-02
Feed will move automatically to the next starting point at the same time as a
user program is switched.
(Normally it moves to the starting point after sewing starts.)
-- --
memo-03
When sewing using programs, the programs which have been set will be sewn
in numerical order. (Cycle sewing mode is set.)
-- --
memo-04
The sewing speed will be fixed at the minimum speed for the maximum pitch of
the sewing data. (Set this to ON if you are concerned that variations in pitch
may cause changes in the sewing speed.)
-- --
memo-05
Increases the presser solenoid lifting force
(Set to ON when using the optional spring for extra-heavy material)
*2 --
memo-06 Enlargement and reduction ratio settings for X and Y become the same. -- --
memo-07 The inner clamping device can be used with pneumatic specifications. -- *3
memo-08 Test feeding is carried out stitch by stitch when the foot switch is depressed. *4 --
memo-09
The sewing start point becomes the reference point for enlargements and
reductions. (The reference point for enlargements and reductions is normally
the center of the sewing frame.)
-- --
memo-0A Work clamp does not close. (KE-432*) -- --
memo-0b Work clamp closes when the machine starts. (KE-432*) -- --
memo-0c
Needle stops in up position during emergency stop.
(EMERGENCY STOP switch is available as an option except for KE-434*, 435*,
484C)
-- --
memo-0d
The bar tacking stitches (with a pitch of less than 1 mm) are also enlarged and
reduced. (Normally stitches with a pitch of less than 1 mm are not enlarged or
reduced.)
-- --
memo-0E
Test feeding will be performed at the same speed as that for actual sewing.
(This is used for checking feeding operation.)
-- --
memo-0F
After sewing is finished, the work clamp automatically opens and closes once
(practice operation).
-- --
*1 ON for KE-434B, 434C, and “--” at other times
*2 ON for solenoid/heavy material specifications of KE-434B, 434C, and “--” at other times
*3 ON when the inner clamping device is being used, and “--” at other times
*4 ON for BE-438B, 438C, and “--” at other times
<Memory switches 10 - 1F>
Initial value
Switch Motion when set to ON
Solenoid
Pneumatic
memo-10
The optional emergency stop switch can be used. (KE-430*, 431*, 432*, 433B,
BE-438*)
-- --
memo-11
On when a two-stage tensioner is used. (Special order device that outputs from
option output No. 1)
(Normally the tension opens when output is OFF, and the tension closes when
option output No. 1 is ON)
-- --
memo-12
Pneumatic wiper can be used. (Special order device except for KE-484C that
outputs from option output No. 2)
-- *5
memo-13
The inner clamping device moves forward at the 1/4-way mark and returns at
the 3/4-way mark for the pattern being sewn.
(The device does not retract at this time, regardless of the setting for
memo-15.)
-- --
memo-14
Solenoid wiper can be used (available as an option except for KE-434*
pneumatic specification and KE-435*).
-- ON
*5 ON for KE-484C, and “--” at other times