3. When propane system is pressurized, apply a 50/50 solution of soap and
water with a soft bristled brush to all connections and look for bubbles.
An expanding bubble or bubbles indicate you have a leak. Repair all
leaks prior to using propane cylinder or appliances. Retighten where
bubbles appear, recheck for leakage using the soap and water solution.
If bubbles indicate you still have a leak - STOP - DO NOT USE the propane
cylinder or appliance(s). Have a qualified propane service person recheck
your propane system and correct leaks before using the propane
system outlet.