Broan QTR140L Fan User Manual


 
Page 4
MODEL QTR140L
SERVICE PARTS
99043902C
Key No. Part No. Description
1 97016466 Housing
2 475 Duct Reducer - 6” to 4”
3 97016450 Duct Connector - 6”
4 98010102 Wiring Plate
5 99170245 Screw, #8-18 X .375
6 97016933 Wire Panel/Harness Assembly
7 99020284 Blower Wheel
8 99080595 Motor
9 99100491 Isolator (4 req’d)
10 97016468 Motor Plate
11 99250959 Washer #8 (4 req’d)
12 99260558 Nut, Hex Lock #8-32 (4 req’d)
* 97017069 Blower Assembly
(includes key nos. 7 thru 12)
13 97017067 Grille Assembly
(includes key nos. 14 & 15)
14 99140199 Grille Spring (2 req’d)
15 99111345 Lens
16 99111293 Spacer (2 supplied)
17 99420665 Thumbscrew, #8-18 x .375
SERVICE NOTE
To remove Blower Assem-
bly:
Unplug motor (8).
Remove thumbscrew (17)
from motor plate (10) ange.
Find the single TAB on the
motor plate (located next to
the receptacle).
Push up near motor plate
tab while pushing out on
side of housing. Or insert a
straight-blade screwdriver
into slot in housing (next to
tab) and
twist screwdriver.
TAB
Order service parts by “Part No.” - not by “Key No.”
9. Remove
light lens.
Carefully insert a
small at-blade
screwdriver be-
tween grille and
lens. Pry lens
out.
8. Push grille
against ceil-
ing.
10. Install light bulbs.
Purchase an incandes-
cent bulb - 100W Max.
Purchase a 4W incan-
descent night light bulb.
Insert bulbs into their
sockets. Replace lens.