9
WIRING DIAGRAMS (CONT’D)
WARNING
Risk of electrical shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels before
operating. Failure to do so can result in electrical shock causing severe injuries or death.
!
FUSED 24 VAC
POWER OUT
G
L1
Class 2 Transformer
Pri: 240 V 60 Hz
Sec: 24 V 60 Hz 40 VA
YEL
YEL
BLK
BLK
BLK
BLK
BLK
BLK
PPL
HEAT 4
HEAT 3
HEAT 2
HEAT 1
PNK
BRN
GRY
WHT
WHT
WHT
WHT
PNK
BLK
BLK
BLK
BLK
BLK
YEL
Open: 93.3°C (200°F)
MRHTL1
WHTWHT
PPL
BLK (HI)
BLU (MED-HI)
RED (LO)
YEL (MED-LO)
MRHTL2
N
P2-3
P2-2
P2-1
P1-4
P1-3
P1-2
P1-1
24V
regulated
RLY PWR2
Heater
Logic
HEAT6 IN
HEAT5 IN
HEAT6
HEAT5
GRY
PNK
PNK
WHT
PNK
PNK
PPL
GRY
PPL
PNK
KC4
24VDC
COM
NO
KC1
24VDC
COM
NO
KC2
24VDC
COM
NO
KC3
24VDC
COM
NO
KC5
24VDC
COM
NO
KC6
24VDC
COM
NO
L2
RED
RED
RED
RED
RED
RED
RED
HEAT 1
E
HTL
KLBDER
HEAT 2
E
HTL
RED
BLK
HEAT 3
E
HTL
RED
BLK
HEAT 4
E
HTL
BLK
RED
BLK
BLK
HEAT 5
RED
E
HTL
BLK
HEAT 6
RED
E
HTL
K7
24VDC
4
62
5
13
PNK
BLU
BLU
ORG
NC
HEAT 5
HEAT 6
HI
Med-Hi
Med-Lo
Lo
M
RED
YEL
MED-LO
LO
BLK
BLK
RED
PPL
ORG
C
BRN
BRN
24 VAC
24 VAC
COMMON OUT
CALL FOR FAN
CALL FOR COOL.
REVERSING VALVE
CALL FOR HEAT 1
CALL FOR HEAT 2
CALL FOR COOL 1
BOARD POWER
SUPPLY
POWER
HEAT 1
HEAT 2
HEAT 3
HEAT 4
VOUT
GND
WHT
YEL
BLK
PPL
VENTILATION SPEED
P2
P1
GRY
T
HEAT INDICATOR
SEASON SELECT
GRY
PPL
PPL
PPL
BLK
HEAT
COOL
FAN
XFMR
VSPOWER
L1
L2COM
L2
L2COM2
BLK BLK
RED
ORG
ORG
BLK
P2-8
P2-4
P2-3
P2-2
P2-1
P2-5
P2-6
P2-7
27 kW 240 VAC
Single phase
Y1
W2
W1
O
Y/Y2
GR
C
F1
5 AMPS
P3
P3-1 P3-2 P3-3
P3-4 P3-5
P3-6
P3-7
WHT
GRY
BRN
PNK
TB
K1K2
K2
WHT
WHT
WHT
BLK
BLK
WHT
WHT
Line voltage wiring:
UL AWM 1015/1230, 600V, 105°C, VW-1,12AWG;
CSA TEW 600V, 105°C, FT1, 12AWG.
Low voltage wiring: same ratings as high voltage
except 18AWG.
Critical Characteristic
1. If any of the original wire, as supplied, must be
replaced, use the same equivalent wire. Wiring
must comply with applicable codes, ordinances
and regulations.
2. Field wiring must comply with applicable codes,
ordinances and regulations. Use only Class 1
wiring inside furnace compartments.
For the use of a two-stage heat thermostat or
an outdoor thermostat, connect between W1
and W2. Make sure that the Season Select
switch is set to the Mild Position.
HI BLACK
MED-HIGH BLUE
MED-LOW YELLOW
LOW RED
FAN MOTOR SPEED COLOR
WIRING COLOR CODE
BLK BLACK
BLU BLUE
BRN BROWN
GRN GREEN
GRY GREY
ORG ORANGE
PNK PINK
PPL PURPLE
RED RED
WHT WHITE
YEL YELLOW
LEGEND
C Capacitor
F1 Fuse
E Heating Element
KC Heating Element
Relay
K Fan Relay
HTL Auto-Reset
Thermal Protector
MRHTL Manual Reset
Thermal Protector
M Fan Motor
TB Terminal Block
T Transformer Class 2
HEAT Heat
L1, L2 240V Line Supply
N Neutral