BRK electronic SCO500 Carbon Monoxide Alarm User Manual


 
7 8
9
WH
AT YOU NEED TO KNOW ABOUT CO
WHAT IS CO?
CO is an invisible, odorless, tasteless gas produced when fossil fuels
d
o not burn completely, or are exposed to heat (usually fire). Electrical
appliances typically do not produce CO.
T
hese fuels include:
W
ood, coal, charcoal, oil, natural gas, gasoline,
kerosene, and propane.
Common appliances are often sources of CO.If they are not properly
maintained, are improperly ventilated, or malfunction, CO levels can rise
quickly. CO is a real danger now that homes are more energy efficient.
“Air-tight” homes with added insulation, sealed windows, and other
weatherproofing can “trap” CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be
discussed with ALL household members.
Mild Exposure: Slight headache, nausea, vomiting, fatigue (“flu-like”
symptoms).
M
edium Exposure:
T
hrobbing headache, drowsiness, confusion, fast
hear
t rate.
Extreme Exposure: Convulsions, unconsciousness, heart and lung
f
ailure. Exposure to Carbon Monoxide can cause brain damage, death.
T
his CO Alarm measures exposure to CO over time. It alarms if CO
le
vels are extremely high in a short period of time, or if CO levels reach
a ce
rtain minimum over a long period of time.The CO Alarm generally
sou
nds an alarm before the onset of symptoms in average, healthy
ad
ults.Why is this important? Because you need to be warned of a
po
tential CO problem while you can still react in time. In many reported
cases of CO exposure, victims may be aware that they are not feeling
w
ell, but become disoriented and can no longer react well enough to
e
xit the building or get help.Also, young children and pets may be the
first affected.The average healthy adult might not feel any symptoms
w
hen the CO Alarm sounds. However, people with cardiac or respiratory
pr
oblems, infants, unborn babies, pregnant mothers, or elderly people
can be more quickly and severely affected by CO.If you experience
e
ven mild symptoms of CO poisoning, consult your doctor immediately!
FINDING THE SOURCE OF CO AFTER AN ALARM
C
arbon monoxide is an odorless, invisible gas, which often makes it
d
ifficult to locate the source of CO after an alarm.These are a few of
the factors that can make it difficult to locate sources of CO:
• House well ventilated before the investigator arrives.
• P
roblem caused by “backdrafting.”
Transient CO problem caused by special circumstances.
Be
cause CO may dissipate by the time an investigator arrives, it may
be d
ifficult to locate the source of CO.
B
RK Brands, Inc. shall not be
obl
igated to pay for any carbon monoxide investigation or service
ca
ll.
POTENTIAL SOURCES OF CO IN THE HOME
Fuel-burning appliances like: portable heater, gas or wood burning
fir
e
place, gas kitchen range or cooktop, gas clothes dryer.
D
ama
ged or insufficient venting:
corr
od
ed or disconnected water
heater vent pipe, leaking chimney pipe or flue, or cracked heat
e
xchanger, blocked or clogged chimney opening.
I
mproper use of appliance/device:
ope
rating a barbecue grill or
vehicle in an enclosed area (like a garage or screened porch).
Transient CO Problems: “transient” or on-again-off-again CO problems
can be caused by outdoor conditions and other special circumstances.
The following conditions can result in transient CO situations:
1. Excessive spillage or reverse venting of fuel appliances caused by
out
door conditions such as:
W
i
nd d
irection and/or velocity, including high, gusty winds.
Heavy air in the vent pipes (cold/humid air with extended periods
between cycles).
• Negative pressure differential resulting from the use of exhaust
fans.
Several appliances running at the same time competing for
limited fresh air.
• Vent pipe connections vibrating loose from clothes dryers,
f
urnace
s, or water heaters.
• Obstructions in or unconventional vent pipe designs which can
amplify the above situations.
2. Extended operation of unvented fuel burning devices (range, oven,
fir
e
p
lace)
.
3. Temperature inversions, which can trap exhaust close to the ground.
4. Car idling in an open or closed attached garage, or near a home.
T
he
se conditions are dangerous because they can trap exhaust in your
home. Since these conditions can come and go, they are also hard to
recreate during a CO investigation.
HO
W CAN I PROTECT MY FAMILY FROM
CO POISONING?
A CO Alarm is an excellent means of protection. It monitors the air and
sou
nds a loud alarm before Carbon Monoxide levels become threatening
f
or average, healthy adults.
A CO Alarm is not a substitute for proper maintenance of home
appl
iances.
To help prevent CO problems and reduce the risk of CO poisoning:
Clean chimneys and flues yearly. Keep them free of debris,
leaves, and nests for proper air flow. Also, have a professional
check for rust and corrosion, cracks, or separations. These
cond
itions can prevent proper air movement and cause back-
drafting. Never “cap” or cover a chimney in any way that would
block air flow.
• Test and maintain all fuel-burning equipment annually. Many local
gas or oil companies and HVAC companies offer appliance
i
nspections for a nominal fee.
• Make regular visual inspections of all fuel-burning appliances.
C
heck appliances for excessive rust and scaling.Also check the
flame on the burner and pilot lights.The flame should be blue.A
y
ellow flame means fuel is not being burned completely and CO
ma
y be present. Keep the blower door on the furnace closed.
Use vents or fans when they are available on all fuel-burning
a
ppliances. Make sure appliances are vented to the outside. Do
no
t grill or barbecue indoors, or in garages or on screen porches.
Check for exhaust backflow from CO sources. Check the draft
hood on a
n operating furnace for a backdraft. Look for cracks on
f
urnace heat exchangers.
Check the house or garage on the other side of shared wall.
Keep windows and doors open slightly. If you suspect that CO
is e
scaping into your home, open a window or a door. Opening
w
indows and doors can significantly decrease CO levels.
I
n addition, familiarize yourself with all enclosed materials. Read
this manual in its entirety, and make sure you understand what to
do if y
our CO Alarm sounds.
REGULATORY INFORMATION FOR
SMOKE/CO ALARMS
REGULATORY INFORMATION FOR CO ALARMS
W
HAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO
Alarms t
o sound when exposed to levels of CO and exposure times as
d
escribed below.They are measured in parts per million (ppm) of CO
o
ver time (in minutes).
U
L2
034 Required Alarm Points*:
• If the alarm is exposed to 400 ppm of CO,IT MUST ALARM
B
ETWEEN 4 and 15 MINUTES.
• If the alarm is exposed to 150 ppm of CO, IT MUSTALARM
B
ETWEEN 10 and 50 MINUTES.
• If the alarm is exposed to 70 ppm if CO, IT MUSTALARM
B
ETWEEN 60 and 240 MINUTES.
* Approximately 10% COHb exposure at levels of 10% to 95% Relative
H
umidity (RH).
T
he unit is designed not to alarm when exposed to a constant level
o
f 30 ppm for 30 days.
CO Alarms are designed to alarm before there is an immediate life
t
hreat. Since you cannot see or smell CO, never assume it’s not present.
An e
x
posure to 100 ppm of CO for 20 minutes may not affect
average, healthy adults, but after 4 hours the same level may cause
head
aches.
An e
x
posur
e t
o 400 ppm of CO may cause headaches in average,
healthy adults after 35 minutes, but can cause death after 2 hours.
S
tandards:
U
nd
e
rwriters Laboratories Inc. Single and Multiple Station
carbon mono
xide alarms UL2034.
Accor
ding to Underwriters Laboratories Inc. UL2034,Section 1-1.2:
C
arbon mono
x
ide alarms covered by these requirements are intended
t
o respond to the presence of carbon monoxide from sources such as,
but not limited to, exhaust from internal-combustion engines, abnormal
operation of fuel-fired appliances, and fireplaces. CO Alarms are intended
t
o a
larm at carbon monoxide levels below those that could cause a loss
of ability to react to the dangers of Carbon Monoxide exposure.”This CO
Alarm monitors the air at the Alarm, and is designed to alarm before CO
le
vels become life threatening.This allows you precious time to leave
t
he house a
nd correct the problem.This is only possible if Alarms are
l
oca
t
ed, installed, and maintained as described in this manual.
Gas Detection at Typical Temperature and Humidity Ranges: The
CO Alarm is not formulated to detect CO levels below 30 ppm typically.
U
L
t
e
s
ted for false alarm resistance to Methane (500 ppm), Butane (300
ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol
(200 ppm) and Carbon Dioxide (5000 ppm).Values measure gas and
v
a
por conce
n
t
r
a
t
ions i
n parts per million.
Audible Alarm: 85 dB minimum at 10 feet (3 meters).
RE
G
U
LA
T
ORY INFORMATION FOR SMOKE ALARMS
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
T
he N
a
tional Fire Protection Association (NFPA), recommends one
Smoke Alarm on every floor, in every sleeping area, and in every
bedroom. In new construction, the Smoke Alarms must be AC powered
a
nd i
n
t
e
r
con
nected. See “Agency Placement Recommendations” for
d
etails. For additional coverage, it is recommended that you install a
Smoke Alarm in all rooms, halls, storage areas, finished attics, and
basements, where temperatures normally remain between 40˚ F (4˚ C)
a
nd
1
00˚ F (3
8˚ C). Make sure no door or other obstruction could keep
smoke from reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
O
n e
v
e
ry level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with the door partly
or com
p
le
tely closed.
In the hall near every sleeping area. If your home has multiple
sleeping areas, install a unit in each. If a hall is more than 40 feet
long (12 meters), install a unit at each end.
At the top of the first-to-second floor stairway, and at the bottom of
t
he b
ase
ment stairway.
Specific requirements for Smoke Alarm installation vary from state to
s
t
a
te and from region to region. Check with your local Fire Department
for current requirements in your area.
It is recommended AC or AC/DC
unit
s be i
nterconnected for added protection.
ABOUT SMOKE ALARMS
B
attery (DC) operated Smoke Alarms:
P
rovide protection even when
ele
ctricity fails, provided the batteries are fresh and correctly installed.
U
nits are easy to install, and do not require professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit
se
nses smoke, all units alarm.They do not operate if electricity fails.
A
C with battery (DC) back-up:
w
ill operate if electricity fails, provided
the batteries are fresh and correctly installed.AC and AC/DC units must
be i
nstalled by a qualified electrician.
O
NELINK
®
Sm
oke Alarms with battery (DC) back-up:
I
nterconnects
w
ith all ONELINK
®
e
nabled Smoke and Smoke/CO Alarms without wires
or connectors, so when one alarm sounds, they all sound.Will operate if
ele
ctricity fails, provided the batteries are fresh and correctly installed.
U
nits are easy to install, and do not require professional installation.
Sm
oke/CO Alarms for Solar or Wind Energy users and battery
b
ackup power systems:
A
C powered Smoke/CO Alarms should only
be operated with true or pure sine wave inverters. Operating this Alarm
w
ith most battery-powered UPS (uninterruptible power supply) products
or sq
uare wave or “quasi sine wave” inverters
w
ill damage the Alarm
.
If you are not sure about your inverter or UPS type, please consult with
t
he manufacturer to verify.
Sm
oke Alarms for the hearing impaired:
Spe
cial purpose Smoke Alarms
shou
ld be installed for the hearing impaired.They include a visual alarm
and an audible alarm horn, and meet the requirements of the Americans
W
ith Disabilities Act. Can be interconnected so if one unit senses smoke,
a
ll units alarm.
Sm
oke alarms are not to be used with detector guards
u
nless the
com
b
i
nation has been evaluated and found suitable for that purpose.
Al
l t
he
se Smoke Alarms are designed to provide early warning of fires if
located, installed and cared for as described in the user’s manual, and if
smo
ke reaches the Alarm. If you are unsure which type of Smoke Alarm
t
o install, refer the National Fire Protection Association (NFPA) Standard
7
2 (National Fire Alarm Code) and NFPA101(Life Safety Code).
N
a
t
iona
l Fire Protection Association, One Batterymarch Park, Quincy, MA
0
2269-9101. Local building codes may also require specific units in new
construction or in different areas of the home.
SPECIAL COMPLIANCE CONSIDERATIONS
This unit alone is not a suitable substitute for complete fire detection
systems
in places housing many people—like apartment buildings,
condom
i
ni
ums, hotels, motels, dormitories, hospitals, long-term health
care facilities, nursing homes, day care facilities, or group homes of
an
y kind—even if they were once single-family homes. It is not a
suitable substitute for complete fire detection systems in warehouses,
industrial facilities, commercial buildings, and special-purpose non-
res
iden
tia
l bui
ldi
ngs which require special fire detection and alarm
systems. Depending on the building codes in your area, this unit may
be used to provide additional protection in these facilities.
The following information applies to all five types of buildings listed
bel
o
w:
I
n ne
w construction, most building codes require the use of AC or AC/DC
powered Smoke Alarms only. AC,AC/DC, or DC powered Smoke Alarms
ca
n be used in existing construction as specified by local building codes.
Re
f
e
r t
o N
FP
A 72 (National Fire Alarm Code) and NFPA 101 (Life Safety
Code), local building codes, or consult your Fire Department for detailed
fire protection requirements in buildings not defined as “households.”
1. Single-Family Residence:
Single family home, townhouse. It is recommended this unit be installed
on e
v
e
r
y level of the home, in every bedroom, and in each bedroom
hallway.
2. Multi-Family or Mixed Occupant Residence:
Ap
ar
tment building, condominium.This unit is suitable for use in
individual apartments or condos, provided a primary fire detection
s
ystem already exists to meet fire detection requirements in common
areas like lobbies, hallways, or porches. Using this unit in common areas
ma
y not provide sufficient warning to all residents or meet local fire
pr
o
t
e
ction ordinances/regulations.
3.
I
ns
tituti
ons:
Hospitals, day care facilities, long-term health care facilities. This unit is
su
it
a
b
le for use in individual patient sleeping/resident rooms, provided
a primary fire detection system already exists to meet fire detection
r
e
quirements in common areas like lobbies, hallways, or porches.
Using this unit in common areas may not provide sufficient warning to
all residents or meet local fire protection ordinances/regulations.
4.
H
otels and Motels:
Also boarding houses and dormitories.This unit is suitable for use inside
individual sleeping/resident rooms, provided a primary fire detection
s
y
s
t
em already exists to meet fire detection requirements in common
areas like lobbies, hallways, or porches. Using this unit in common areas
ma
y no
t provide sufficient warning to all residents or meet local fire
protection ordinances/regulations.
5. Warehouses/Commercial Buildings:
D
O NOT use this Smoke/CO Alarm in warehouses, industrial or
com
mercial buildings, special-purpose non-residential buildings, RVs,
bo
ats, or airplanes.This Smoke/CO Alarm is specifically designed for
residential use, and may not provide adequate protection in non-resi-
dential applications.
Printed in Mexico M08-0146-004 J1 03/07
F
ir
st Alert
®
is a r
e
gistered trademark of the First Alert Trust used
under license.
ONELINK
®
is a registered trademark of BRK Brands, Inc.
L
IMI
T
E
D
W
ARR
ANTY
BRK Brands, Inc., ("BRK") the maker of First Alert
®
brand products warrants that for a period of five years from the date of purchase, this product will be
f
r
e
e f
rom defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective
during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replace-
me
n
t may be made with a similar product of equal or greater value.This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of
purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter,
mod
ify or a
ny way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper
voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center.
F
ur
t
he
r, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.
BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited
by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty.
Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied
warranty lasts, so the above limitations or exclusion may not apply to you.This warranty gives you specific legal rights, and you may also have other rights
t
ha
t v
ary from state to state or province to province.
How to Obtain Warranty Service
S
ervice:
I
f service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at
1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through Friday.To assist us in serving you, please have the model number and date of
purchase available when calling.
F
or
W
arran
ty Service return to:
B
R
K Br
a
nds, Inc., 25 Spur Drive, El Paso,TX 79906
Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose with
respect to battery.
TROUBLESHOOTING GUIDE
If the
Alarm... Problem... You should...
Horn "chirps" about once per minute;
V
oice:
"Re
place battery in [Location]" every 5
hour
s
Low battery warning. Install two new AA batteries
*.
H
orn does three rapid "chirps" every minute;
Voice: "Detector error in [Location, example
"K
itchen"], please see manual" repeated every
5 hour
s; L
ED has 3 rapid flashes with "chirps".
M
ALFUNCTION SIGNAL.
D
evice is not working
properly, and needs to be replaced.
U
nits under warranty should be returned to
manufacturer for replacement. See “Limited
W
arranty” for details.
T
he Alarms are linked but do not communicate
w
it
h each other.
P
ossible interference. Reference the Wireless
O
pe
ration section of this manual.
M
ove Alarms to different locations.Add an
ad
d
itional Alarm between the unresponsive
Alarms to route the signal around obstructions.
C
arb
on Monoxide Alarm ONLY:
CO Alarm goes back into alarm 4 minutes after
y
ou Silence it.
CO levels indicate a potentially dangerous
sit
uation.
IF YOU ARE FEELING SYMPTOMS OF CO
P
OISONING, EVACUATE your home and call
9
1
1 or the Fire Department. Refer to "If The CO
Alarm Sounds" for details.
C
O
Alarm sou
nds f
r
e
q
ue
n
tly even though no high
le
v
els of CO are revealed in an investigation.
T
he C
O
Alarm ma
y be i
m
pr
ope
r
ly located. Refer
t
o
“Where to Install This Alarm” for details.
Rel
oca
t
e y
our
Alarm
.
I
f f
requent alarms
con
t
inue, have home rechecked for potential
CO problems.You may be experiencing an
i
ntermittent CO problem.
Sm
o
k
e Alarm ONLY:
Smo
k
e Alarm sounds when no smoke is visible.
U
n
wanted alarm may be caused by non-
e
mergency source like cooking smoke.
Si
le
nce Alarm using manual button; clean the
Alarm
’s cover with a soft, clean cloth. If frequent
u
nwanted alarms continue, relocate your Alarm.
Alarm may be too close to a kitchen, cooking
a
p
pliance, or steamy bathroom.
*F
or a l
is
t o
f acce
p
t
able replacement batteries, see “Regular Maintenance.”
I
f y
ou ha
v
e questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m.(CST)
This Smoke/CO Alarm is intended for residential use. It is not intended
f
or use in industrial applications where Occupational Safety and Health
Administration (OSHA) requirements for Carbon Monoxide Alarms must
be met.The Smoke Alarm portion of this device is not intended to alert
hear
ing impaired residents. Special purpose Smoke Alarms should be
installed for hearing impaired residents (CO Alarms are not yet available
f
or the hearing impaired).
Smoke/CO Alarms may not waken all individuals. Practice the escape
plan at least twice a year, making sure that everyone is involved – from
k
ids to grandparents. Allow children to master fire escape planning and
practice before holding a fire drill at night when they are sleeping.
If children or others do not readily waken to the sound of the Smoke/CO
Alarm
, or if there are infants or family members with mobility limitations,
make sure that someone is assigned to assist them in fire drill and in
the event of an emergency. It is recommended that you hold a fire drill
w
hile family members are sleeping in order to determine their response
to the sound of the Smoke/CO Alarm while sleeping and to determine
whether they may need assistance in the event of an emergency.
Sm
oke
/C
O
Al
arms cannot work without power.
Ba
ttery operated units
ca
nnot work if the batteries are missing, disconnected or dead, if the wrong
type of batteries are used, or if the batteries are not installed correctly.
A
C units cannot work if the AC power is cut off for any reason (open fuse
or cir
cuit breaker, failure along a power line or at a power station, electrical
fire that burns the electrical wires, etc.). If you are concerned about the
l
imitations of battery or AC power, install both types of units.
T
his Smoke/CO Alarm will not sense smoke or CO that does not
rea
ch the sensors.
I
t will only sense smoke or CO at the sensor.
Smoke or CO may be present in other areas. Doors or other obstructions
ma
y affect the rate at which CO or smoke reaches the sensors. If bed-
r
oom doors are usually closed at night, we recommend you install an
a
larm device (Combination CO and Smoke Alarm, or separate CO
Alarms a
nd Smoke Alarms) in each bedroom and in the hallway
be
tween them.
This Smoke/CO Alarm may not sense smoke or CO on another level
o
f the home.
E
xample: This alarm device, installed on the second floor,
ma
y no
t sense smoke or CO in the basement. For this reason, one
alarm device may not give adequate early warning.
Recommended minimum protection is one alarm device in every
sle
eping area, every bedroom, and on every level of your home. Some
experts recommend battery powered Smoke and CO Alarms be used in
conjunction with interconnected AC powered Smoke Alarms. For details,
se
e “About Smoke Alarms” for details.
Sm
oke/CO Alarms may not be heard.
T
he alarm horn loudness meets or
e
xceeds current UL standards of 85 dB at 10 feet (3 meters). However, if
the Smoke/CO Alarm is installed outside the bedroom, it may not wake up
a sound sleeper or one who has recently used drugs or has been drinking
a
lcoholic beverages.This is especially true if the door is closed or only
partly open. Even persons who are awake may not hear the alarm horn
if the sound is blocked by distance or closed doors. Noise from traffic,
s
tereo, radio, television, air conditioner, or other appliances may also
prevent alert persons from hearing the alarm horn.This Smoke/CO Alarm
is not intended for people who are hearing impaired.
The Alarm may not have time to alarm before the fire itself causes
damage, injury, or death, since smoke from some fires may not
reach the unit immediately. Examples of this include persons
sm
oking in bed, children playing with matches, or fires caused by
v
iolent explosions resulting from escaping gas.
T
his Smoke/CO Alarm is not a substitute for life insurance.
Though this Smoke/CO Alarm warns against increasing CO levels or the
pr
esence of smoke, BRK Brands, Inc. does not warrant or imply in any
w
ay that they will protect lives. Homeowners and renters must still insure
their lives.
T
his Smoke/CO Alarm has a limited life.
Alt
hough this Smoke/CO
Alarm a
nd all of its parts have passed many stringent tests and are
designed to be as reliable as possible, any of these parts could fail at
a
ny time.Therefore, you must test this device weekly.The unit should
be r
eplaced immediately if it is not operating properly.All Smoke/CO
Alarms need to be replaced every 5 years. All Smoke Alarms need to be
r
eplaced every 10 years.
T
his Smoke/CO Alarm is not foolproof.
L
ike all other electronic
d
evices, this Smoke/CO Alarm has limitations. It can only detect smoke
or CO that reaches the sensors. It may not give early warning of the
sour
ce of smoke or CO is in a remote part of the home, away from the
a
larm device.
G
ENERAL LIMITATIONS OF SMOKE/CO ALARMS
1110 12
For your records, please record:
Date Purchased: _______________________________
W
here Purchased: __________________________________________
D
ate Installed: ____________/____________Month/Year
Replacement date is five years after installation: ________/______
Month/Year
NOTE: End of Life Signal — Once the unit reaches the end of its
lifecycle, the MALFUNCTION SIGNAL will sound once a minute to
indicate the need to immediately replace the Alarm.
REGULAR MAINTENANCE
This unit has been designed to be as maintenance-free as possible, but
there are a few simple things you must do to keep it working properly.
Use only the replacement batteries listed below.The unit may not
opera
te pr
operly w
ith other batteries. Never use rechargeable
batteries since they may not provide a constant charge.
Test it at least once a week.
Clean the Smoke/CO Alarm at least once a month; gently vacuum the
out
side of the Smoke/CO Alarm using your household vacuum’s soft
brush attachment.A can of clean compressed air (sold at computer
or o
ffice supply stores) may also be used. Follow manufacturer
i
nstructions for use. Test the Smoke/CO Alarm. Never use water,
cleaners or solvents since they may damage the unit.
If the Smoke/CO Alarm becomes contaminated by excessive dirt,
dust and/or grime, and cannot be cleaned to avoid unwanted
a
larms, replace the unit immediately.
Relocate the unit if it sounds frequent unwanted alarms. See “Where
This Alarm Should Not Be Installed” for details.
Choosing a replacement battery:
Your Smoke/CO Alarm requires two standard AA batteries.
T
he f
o
l
lowing batteries are acceptable as replacements:
E
ne
r
g
izer E91
.
These batteries are available at many local retail stores.
Act
ua
l b
attery service life depends on the Smoke/CO Alarm and the
environment in which it is installed. All the batteries specified above
ar
e acce
ptable replacement batteries for this unit. Regardless of the
manufacturer’s suggested battery life, you MUST replace the battery
immediately once the unit starts “chirping” (the “low battery warning”).
To replace the batteries (without removing Alarm from
the cei
l
i
n
g or wall):
1. Open the battery compartment.
2. Press tabs A and B as shown in the
d
iagr
a
m and remove each battery.
3
.
Insert the new batteries, making sure
they snap completely into the battery
com
partment. Match the terminals
on t
he e
nds o
f t
he b
a
tteries with the
terminals on the unit.
4. Close the battery compartment, and
then test the unit by pressing the
T
e
s
t/Si
le
nce b
utt
on
.
A
B
WE
EKLY TESTING
N
EVER use an open flame of any kind to test this unit. You
m
ight accidentally damage or set fire to the unit or to your
h
ome.The built-in test switch accurately tests the unit’s
opera
tion as required by Underwriters Laboratories, Inc. (UL).
NEVER use vehicle exhaust! Exhaust may cause permanent
dama
ge and voids your warranty.
• DO NOT stand close to the Alarm when the horn is sounding.
Ex
posure at close range may be harmful to your hearing.
W
hen testing, step away when horn starts sounding.
I
t is important to test this unit every week to make sure it is working
pr
operly.Using the test button is the recommended way to test this
Smoke/CO Alarm.
Y
ou can test this Smoke/CO Alarm by
pr
essing and holding the
T
est/Silence button on the Alarm cover until Alarm
V
oice
sa
ys “Testing”
(ty
pically 3-5 seconds).
During testing, you will see and hear the following sequence:
The Alarm
V
oice
w
ill say “Testing.” The
H
orn
w
ill sound 3 beeps,
p
ause, 3 beeps.The Alarm
V
oice
w
ill say “Warning, evacuate
smo
ke in [Location, example: “Kitchen”]. Evacuate.”The
P
ower/Smoke LED
flashe
s Red and the
C
O LED
w
ill be Off.
N
ext the
H
orn
w
i
ll sound 4 beeps, pause, 4 beeps.The Alarm
Voice will say “Warning, evacuate carbon monoxide in [Location,
e
xample: “Kitchen”]. Evacuate.” The
P
ower/Smoke LED
w
ill be
O
ff and the
C
O LED
flashe
s Red.
I
f the unit does not alarm, make sure the batteries are correctly installed,
and test again. If the unit still does not alarm, replace it immediately.
S
ILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning “chirp”
f
or up to 8 hours.You can silence the low battery warning “chirp” by
pressing the Test/Silence button on the alarm cover.
Once the low battery warning “chirp” silence feature is activated, the unit
con
tinues to flash the Green light twice a minute for 8 hours.After 8
hours, the low battery “chirp” will resume.
Replace the batteries as
s
oon as possible; this unit will not operate without battery power!
T
o deactivate this feature:
P
ress the Test/Silence button again.The unit
will go into Test Mode and the low battery warning will resume (LED
flashes and unit sounds “chirp” once a minute).
LATCHING FEATURES
Alarm Latch is activated after an Alarm is exposed to alarm levels of
smoke or carbon monoxide. After smoke or CO levels drop below alarm
levels, the
“Smoke/Power” LED and/or the “CO” Red LED will begin to
flash On for 2 seconds/Off for 2 seconds. It will continue to flash or
“latch” for about 15 minutes, to give you time to determine which unit
i
nitiated the alarm.
Low Battery Latch is activated when the Alarm is in the "low battery
cond
ition".
W
hen this occurs, the
Sm
oke/Power
L
ED flashes Green
O
n for 2 seconds/Off for 2 seconds for about 15 minutes.This feature
is designed to help you identify which Alarm needs to have the battery
r
eplaced. Although, the Alarm will sound the low battery chirp approxi-
ma
tely once every minute, sometimes during the initial stages of "low
battery", the Alarm will chirp in greater intervals than one minute, some-
t
imes up to several hours, until the battery reaches a steady low battery
le
vel.This innovative feature eliminates the frustration of waiting for
and/or identifying which unit is chirping.
A
GENCY PLACEMENT RECOMMENDATIONS
NFPA 72 (National Fire Code) Chapter 11
“For your information, the National Fire Protection Association's
Standard 72,reads as follows:”
“1
1.5.1 One- and Two-Family Dwelling Units.”
“11.5.1.1 Smoke Detection.
Where required by applicable laws, codes, or
s
tandards for the specified occupancy, approved single- and multiple -
s
tation Smoke Alarms shall be installed as follows: (1) In all sleeping
rooms Exception: Smoke Alarms shall not be required in sleeping rooms
i
n existing one- and two-family dwelling units. (2) Outside of each sepa-
r
ate sleeping area, in immediate vicinity of the sleeping rooms.
(3) On each level of the dwelling unit, including basements Exception: In
e
xisting one- and two family dwelling units, approved Smoke Alarms
powered by batteries are permitted.”
A.11.8.3 Are More Smoke Alarms Desirable?
T
he required number
o
f Smoke Alarms might not provide reliable early warning protection
for those areas separated by a door from the areas protected by the
r
equired Smoke Alarms. For this reason, it is recommended that the
house
holder consider the use of additional Smoke Alarms for those
ar
eas for increased protection.The additional areas include the base-
me
nt, bedrooms, dining room, furnace room, utility room, and hallways
no
t protected by the required Smoke Alarms.The installation of Smoke
Alarms i
n kitchens, attics (finished or unfinished), or garages is not
norma
lly recommended, as these locations occasionally experience
cond
itions that can result in improper operation.”
C
alifornia State Fire Marshal (CSFM)
E
arly warning detection is best achieved by the installation of fire detection
equipment in all rooms and areas of the household as follows: A Smoke
Alarm i
nstalled in each separate sleeping area (in the vicinity, but outside
be
drooms), and Heat or Smoke Alarms in the living rooms, dining rooms,
bedrooms, kitchens, hallways, finished attics, furnace rooms, closets,
ut
ility and storage rooms, basements, and attached garages.