Prime the Water Pump
1. Remove priming plug from top of pump.
2. Fill pump with clean, clear water up to top of discharge
outlet.
3. Replace priming plug.
Locate Strainer Basket Into Water Source
Place strainer basket into water to be pumped. Basket must
be fully immersed in water.
Typical Water Pump Shown
Discharge Head
- 200 feet (61m)
Maximum
Suction Head
- 25 feet (8m)
Maximum
Total Head
- 225 feet (69m)
Maximum
NOTICE
Improper treatment of water pump can damage it and
shorten its life.
Be sure pump chamber is filled with water before starting the
engine. NEVER run pump without priming.
NOTICE
Improper treatment of water pump can damage it and
shorten its life.
NEVER operate pump without strainer connected to end of
suction hose.
Keep strainer out of sand or silt, place in bucket or on stones.