Breckwell P2000FS Stove User Manual


 
B. WHEN VENT PIPE EXTENDS TO
CHIMNEY TOP (Refer to Figure 15)
1. You will need a pipe length equal to the
chimney height (from hearth) plus 6
inches. If outside combustion air is to
be used, you will need a pipe length
(see “COMBUSTION AIR SUPPLY)
equal to the chimney height plus 12
inches.
2. Attach cerablanket wrap to that end of
vent pipe that will connect to the stove.
Use 12-inch lengths of light gauge
metal wire (not included) or metallic
tape (not included). This is to protect
interior components from excess heat.
3. Set the insert on the hearth and slide it
in far enough to attach the vent pipe
(and combustion pipe if used).
4. Attach flashing (refer to Figure 14),
route power cord out the side nearest a
120V receptacle. Slide in insert.
5. Measure and build chimney top. Cut
out hole for vent pipe (and combustion
air intake pipe, if used). Install and seal
with a non-hardening mastic to prevent
water leakage. Install the vent cap.
C. WHEN VENT PIPE EXTENDS
THROUGH CHIMNEY BLANKING
PLATE (Masonry Fireplaces Only)
(Refer to Figure 15)
1. You will need a pipe length that
extends 12” above the blanking plate.
NOTE: This installation is optional but
not recommended. Outside combustion
air cannot be drawn from the chimney
cavity in this installation.
2. Attach cerablanket wrap to that end of
vent pipe that will connect to the stove.
Use 12-inch lengths of light gauge
metal wire (not included) or metallic
tape. This is to protect interior
components from excess heat.
3. Measure and build blanking plate. Cut
out hole for vent pipe (and combustion
air intake pipe, if used). Install and
carefully seal blanking plate with non-
hardening mastic. Failure to properly
seal may result in smoke spillage.
4. Slide vent pipe (and intake pipe if used)
up through the blanking plate hole,
leaving enough to pull back down.
5. Set the insert on the hearth, adjust the
leveling bolts on the rear sides, and
slide it in far enough to attach the vent
pipe (and combustion air pipe if used).
Be sure to seal where the pipe passes
through the blanking plate.
6. Attach flashing (refer to Figure 14),
route power cord out the side nearest a
120V receptacle. Slide in insert.
INSTALLATION
1
1
FIGURE 15