Bradford-White Corp UTW465S60FR*N Water Heater User Manual


 
Page 46
Step 8. To resume operation, follow the instructions located on the water heater
lighting instruction label. Or, use the lighting instructions located
in the water heater installation and operating manual.
Inner Door Removal Procedure
Step 1. Move the gas control power switch to the “OFF” po-
sition.
Step 2. Unplug the water heater from the wall outlet.
Step 3. Remove the outer door.
Step 4. Remove (4) 1/4” hex drive screws from the right side
inner door.
Step 5. Remove (3) 1/4” drive screws from the left side
burner door.
Inner Door Removal
G
as control power
switch
Blower (water
heater) power cord
Connectors attached to
resettable thermal switch
Outer door
(3) 1/4” hex
drive screws
(4) 1/4” hex drive
screws
Right side
inner door
46