Installation (continued)-
MINIMUM CLEARANCES
WARNING
Failure to adhere to these installation and operating instructions may
create a hazard to life and property and will nullify the warranty.
This installation shall allow access to the front of the water heater and adequate
clearance shall be provided for servicing and operating this water heater. The
water heater may be installed on either a combustible or non-combustible floor.
If the water heater is to be installed directly on carpeting, it shall be installed on
top of a metal or wood panel (or equivalent) extending beyond the full width and
depth of the appliance by at least three (3) inches (7.6 cm) in any direction or, if
the appliance is to be installed in an alcove or closet, the entire floor shall be
covered by the panel. If the rating plate or the label on the front of the
heater specifies minimum clearances less than those listed in the below
table, the water heater may be installed in accordance with the
minimum clearances listed on the rating plate or the label on the front of
the heater.
If it is necessary to install this water heater in an alcove, use the clearances
listed in Figure 1.
Figure 1