Bradford-White Corp Convection Heater Electric Heater User Manual


 
11
Combustion Air Supply
Provide adequate air for combustion and ventilation. An insufficient supply of air
will cause recirculation of combustion products resulting in air contamination
that may be hazardous to life. Such a condition often will result in a yellow,
luminous burner flame, causing carboning or sooting of the combustion
chamber, burners and flue tubes with possible damage to the water heater.
When an exhaust fan is installed in the same room with a heater, sufficient
openings for air must be provided in the walls. Undersized openings will cause
air to be drawn into the room through the chimney, causing recirculation of
combustion products.
Confined Spaces
Confined spaces are spaces defined as having less than 50 ft.
3
of space per
1,000 BTU (15m
3
/.29kw) per hour of input.
Unconfined Spaces
In unconfined spaces in buildings, infiltration may be adequate to provide air for
combustion, ventilation and dilution of flue gases. However, in buildings of tight
construction (for example, weather stripping, heavily insulated, caulked, vapor
barrier, etc.), additional air may need to be provided using the methods
described above under CONFINED SPACES: All Air From Outdoors or
SPECIALLY ENGINEERED INSTALLATIONS.
WARNING
Liquefied petroleum gases/propane gas are heavier than air and will remain
at floor level if there is a leak. Basements, crawl spaces, closets and areas
below ground level will serve as pockets for accumulation of leaking gas.
Before lighting, smell all around the appliance area for gas. Be sure to smell
next to the floor.
IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do not use any telephone in your
building.
Immediately call your gas supplier from a neighbor’s telephone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
DO NOT OPERATE APPLIANCE UNTIL LEAKAGE IS CORRECTED!
IMPORTANT
The flow of combustion and ventilating air must not be obstructed.
Do not block or in any way restrict jacket air inlet slots located the
bottom front of the water heater.
INTERNET VERSION FOR REFERENCE ONLY