Bradford-White Corp 238-46411-00A Water Heater User Manual


 
10. Thread new element(s) clockwise into tank. Tighten
element(s) with a 1 ½" deep well socket or wrench. Do
not over tighten. Over-tightening may damage gasket.
Note: Clean any debris from element(s) fitting to tank.
Lubricate element(s) threads as needed with thread
lubricant.
11. Be sure tank is filled with water and check for leaks.
12. Reconnect wire leads to element(s) terminal block.
13. Replace thermostat(s) protector and insulation.
14. Replace access cover(s).
15. Restore electrical power.
Thread
element(s)
clockwise
into tank
Reconnect wires
leads to element(s)
terminal block
16. Place appropriate label (supplied
with kit) so it covers electrical
information on water heater rating
plate.
Note: Be certain not to cover model
number, serial number and capacity
information.
Cover electrical information only
with appropriate overlay
Water heater rating plate
Page 5 of 5
9. Apply new gasket(s) to new element(s) from
conversion kit.
Note: Make sure gasket is seated flat against
element flange without rolls or gaps.
Gasket
Element
flange