Bosch Appliances R 40 HE Boiler User Manual


 
7
General notes
6 720 611 138 GB (03.11)
Clearances
Your installer will have provided adequate space around the appli-
ance for safety and servicing access. Do not restrict this space
with the addition of cupboards, shelves etc. next to the appliance.
Room thermostat
A room thermostat should be fitted to control the central heating.
Refer to the instructions supplied with the thermostat for informa-
tion on siting and setting.
Thermostatic radiator valves
It is recommended that this type of valve is fitted to all the radia-
tors. It is a requirement that they are fitted, at least, in the sleeping
areas.They should conform to the requirements of BS2767:10.
Time Control
Separate time control of the space heating and the hot water sys-
tem is required using a twin-channel programmer or two or more
separate timers.
Cylinder Thermostat
A cylinder thermostat must be fitted to the cylinder which, when
used with a motorised valve, will give close control of the water
temperature.
Left-hand side 10 mm
Right-hand side 10 mm
In Front 600 mm
Above Casing (Vertical Flue) 200 mm
Above Flue Turret 30 mm
Below 200 mm
Table 1