Bosch Appliances MX938I Home Security System User Manual


 
7.0 Setup and Walk Testing
IMPORTANT
Before walk testing, the system should be fully wired,
powered, and programmed.
Configure LED Configuration Switch (S1) to LED ON.
Replace the front cover.
NOTE: All testing must be performed with the
front cover in place.
Wait at least 2 minutes (with no motion in the
coverage area) for the detector to setup.
Walk test across the coverage pattern.
The edge of the coverage is determined by
activation of the LED.
Walk test the unit from both directions to determine the
boundaries.
IMPORTANT
On 2-wire systems, configure the LED to OFF when
finished with walk tests.
8.0 Maintenance
The range and coverage should be checked in accordance with
the Walk Testing section (6.0) on a regular basis.
Consult the Control Panel’s User's Guide for the procedure on
performing a zone test. Performing a zone test on a regular
basis assures an alarm output prior to arming the system.
Excessive handling of the mirror surfaces may lead to
performance degradation.
9.0 Coverage Patterns
Refer to the mirror module and pattern drawings for masking
information.
Before masking, be sure the chosen mirror surface is the correct
one. When removing masking, remember, many adhesives will
either destroy the mirror’s surface or leave residue behind to
reduce coverage performance.
0369 Meters 3 6 9
0
10
20
30
10
20
30
TOP VIEW
010 1020 2030 Feet 30
0
10
AR8-13 SIDE VIEW
(Cross Section of 2 Opposite Zones)
0
3
9
6
3
0
9
6
3
Meters
010 1020 20
30 Feet
30
0
10
15
AR13-18 SIDE VIEW
(Cross Section of 2 Opposite Zones)
0
Meters
3
6
9
3
6
9
3
0
4.5
0
10
20
30
10
20
30
0369 Meters 3 6 9
© 2004 Bosch Security Systems
130 Perinton Parkway, Fairport, New York, USA 14450-9199
Customer Service: (800) 289-0096; Technical Support: (888) 886-6189
03/04
MX938i Installation Instructions
P/N: 45988F Page 4