7CONFIGURATION EXAMPLES
Refer to Figures 3 – 6 for various connection option guidelines.
1. The control code outputs from multiple Allegiant Series Switchers are combined so that each system can
control any of the common cameras. If the switcher is close enough, the supplied data interface cable may be
used directly. If a switcher is beyond the distance of the supplied cable, the cable can be spliced to a user-
supplied shielded twisted pair that is connected to the Signal Distribution outputs of the remote switcher.
2. A Code Merger can combine control data generated by any device generating biphase control code. This
allows each control device to operate any of the system’s cameras.
ALLEGIANT Video Matrix
ALLEGIANT Video Matrix
ALLEGIANT Data Unit
CODE
POWER
Allegiant
RECEIVER
DRIVER
Biphase
Data Cable
(Supplied)
Typical Pan/Tilt/Zoom
Equipped Camera Site
4 Ch. Code Merger
Allegiant Switcher
Allegiant Switcher
Typical AutoDome Camera Sites
Up to 1.5km (5000 feet)
using 1mm
2
(18AWG)
Shielded Twisted Pair
Biphase
Data Cable
(Supplied)
Biphase
Control Code
LTC 8570 Series = 32 Separate Outputs
LTC 8572 Series = 64 Separate Outputs
(Any Input)
(Any Input)
ALLEGIANT Video Matrix
Allegiant Switcher
(Any Input)
Up to 1.5km (5000 feet)
using 1mm
2
(18AWG)
Shielded Twisted Pair
Modified
Data Cable
BOSCH
ALLEGIANT Data Unit
CODE
POWER
Signal Distribution Unit
Site 3
Site 2
Site 1
Figure 3 - Code Merger Unit With Multiple Allegiant Series Systems
Figure 4 - AutoDome Controller Combined with Allegiant Series System
ALLEGIANT Video Matrix
ALLEGIANT Data Unit
CODE
POWER
Allegiant
RECEIVER
DRIVER
Modified
Data Cable
Typical Pan/Tilt/Zoom
Equipped Camera Site
2-Ch. Code Merger
LTC 5136 Series
AutoDome Controller
Allegiant Switcher
Typical AutoDome Camera Sites
Up to 1.5km (5000 feet)
using 1mm
2
(18AWG)
Shielded Twisted Pair
Biphase Data Cable
(Supplied)
Biphase
Control Code
LTC 8569 Series = 32 Separate Outputs
LTC 8571 Series = 64 Separate Outputs
Converter Box
Supplied with
LTC 5136
Cable
Splice
Up to 1.5km (5000 feet)
using 1mm
2
(18AWG)
Shielded Twisted Pair
(Any Input)
(Any Input)