Bosch Appliances F.01U.278.516 Home Security System User Manual


 
Relay Unit Operation | en 21
Bosch Security Systems User Manual F.01U.278.516 | V1.0 | 2012.11
5 Operation
5.1 Adjusting the loudspeaker volume
When the Relay Unit is in standby mode:
Press to increase the volume.
Press to decrease the volume.
5.2 Consulting the alarm or event buffer
The Relay Unit uses an alarm buffer and an event buffer for display indication.
The following alarms and messages are stored into the alarm buffer:
call for help
call for assistance
reserve call (call for help 2)
technical call
fire alarm
battery low message
error message
disconnection of a Relay Unit from the RS-485 bus
If alarms are repeated, only the least recent entry remains in the buffer. The call for assistance
replaces the call for help, the reserve call and the technical call in the alarm buffer.
In addition to all the alarms, all possible entries are stored in the event buffer.
The following messages are directly stored into the event buffer:
acknowledgement MIYN46, sent by an MIYN46 Wall Transmitter, MIYS35 or MIYS37
Transmitters
acknowledgement by MIYS35 or MIYS37 Transmitters
local acknowledgement, an acknowledgement at the Main Unit or Relay Unit
daily message check
personnel arrival message (A, B, C and D)
personnel departure message
power outage of a receiver unit
return of power at a receiver unit
backup battery low of a receiver unit
interruption of the RS-232 connection interface between the Main Unit and a PC
return of the RS-232 connection interface between the Main Unit and a PC
connection of a Relay Unit to the RS-485 bus
transmission of the event "door" by an MIYRAC Wireless Contact.
The event buffer will normally be filled with the last 18 or 100 entries.
In the alarm buffer, only the active alarms are present.
NOTICE!
The alarm and event buffers have a capacity of 18 or 100 entries. See the maximum number of
events buffered, in the Main Unit user manual.