10.7 Output Programming: Program Addresses (2734, 2735, 2736)
Output programming defines the event, partition, and type of alarm (burglary or fire) that will trigger each of the three physical outputs on
the control panel.
See section 3.0 for the location of the physical outputs on the control panel.
See Glossary (section 6.4) for further details.
0
Latch on ANY Zone Alarm**
ON during Entry Pre-Alert/Exit Warning
ON for 10 sec. after pressing [System Reset]
ON when system is Armed
Ground Start
System Status (ready to arm)
Zone Alarm
Zone Alarm delayed by 20 sec.
Keypad Sounder Output
Access Output (10 sec. pulse)
1
2
3
4
5
6
7
8
9
12
DD
Data Digit
** = This includes invisible zones. See glossary for further details.
*** = See section 6.4 for description of this option.
Select Option
Keyfob
*1
Alarm
Programmable Output 1
Programmable Output 2
2734
2736
6 3
2 3
Output Address Default
3 32735
On during battery test
*3
*0
Panic Duress Output***
Programmable Output 1 will
be ON for 10 seconds after
pressing [System Reset].
Programmable Output 2 will
be OFF for 10 seconds after
pressing [System Reset].
0
1
2
3
3
Armed Full
Armed Partial
Disabled
DD
Options
Armed Any
Burglar Alarm
Fire Alarm
Disabled
Burg and Fire Alarm
DD
0
1
2
3
Options
Data Digi
t
1
2
0
1
2
RF3334
Disabled
Momentary
Toggle
Momentary
Toggle
Auxillary Key
Auxillary Key
Option Key
Option Key
Options
DD
3
4
*0