Bosch Appliances BC2600RA Water Heater User Manual


 
4
Installation Instructions
3.
Before Installation
Do Not Use Equipment for Purposes Other Than Those Specified
Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in
order to ensure full warranty coverage.
WARNING
CAUTION
Check the Gas
Check that the data plate (located inside of front cover) or
a temporary label (located on the front cover)
indicates the correct type of gas.
Check that the gas supply line is sized for
178 MJ/hr for this unit.
DO NOT OPERATE WITH ANY OTHER GAS TYPE.
Check the Power
The power supply required is 240/230VAC, at 50Hz.
Using the incorrect voltage may result in fire or
electric shock.
Warning labels
Located on the right side of the casing -PLEASE READ THESE LABELS CAREFULLY!
Use Extreme Caution if Using With a Solar Pre-Heater
A solar transfer valve must be installed with all solar applications when using Bosch Eco 26+.
Solar systems installed without a solar transfer valve will void all Bosch warranty.
For NG Gas
MODEL BC2600RA
GAS TYPE
GAS CONSUMPTION
HEAT OUTPUT
ELECTRICAL RATING
RATED POWER
HOT WATER SUPPLY CAPACITY
GAS PRESSURE TEST POINT
GAS SUPPLY PRESSURE
: NG
: 178MJ/hr
: 45.7kW
: AC240/230V 50Hz
: 56.0W
: 26L/min RAISED 25°C
: MAX : 0.73kPa
: MIN : 0.18kPa
MAX 3 0kP