Push Display (Example) Description
0 V37.02 02.03.06
or
WIEGAND
Software versions and date of
the downloader - every 5 sec.
alternating with the display of
the reader interface.
(= default page)
1 99999876543210 A BOSCH serial number and bus
address:
A = address 1
...
H = address 8
2 02.06 15:35:15 Current date and time
3 Dig. IO: :::::::::::::::: Display of the digital contacts:
setted input signals will be
shown with an extension above -
output signal with an extension
below
3a Dig. I1: :::::::::::::::: If there are I/O-Boards con-
nected the signals will be shown
on separate pages.
3b Dig. I2: ::::::::::::::::
3c Dig. I3: ::::::::::::::::
4 MAC 0010174C8A0C MAC-address
5 N AMC-1234-5678 Network name of the AMC
6 I 192.168.10.18 IP-address of the AMC
7 H 192.168.10.10 IP-address of the host computer
8 DHCP 1 DHCP-status:
1 = on
0 = off
9 D 192.168.10.1 IP-address of the DNS server
10 Host: + "C" Host activity:
+ = online
- = offline
"C" = Counter of the received
data packages from the host
interface
Tabelle 6.1 Display pages