42 en | Installing AMC2 4W
F.01U.024.965 | V.4 | 2006.09 Installation manual Bosch Security Systems
Fig. 5.19 Wet mode and dry mode of the AMC2 4W relay outputs
For the protection of damage the relay keep in mind, that ...
– the maximum switching current is 1,25A
– the maximum switching voltage is 30V DC
– ohm resistive load can be connected to the relay, only
– inductive loads have to be short circuited using recovery
diodes - see: Figure 5.20. These diodes (BAX12A) are sup-
plied with every AMC2 4W package.
– If you need higher voltage for special constructions you
can connect external relays to the outputs. Recommended,
depending on the power supply mode, are the relay types
of the company Wieland:
• Flare move 12DC1W10A
• Flare move 24DC1W16A
But you can also use products of manufacturer in your
country - take care that the values of the product are iden-
tical with the products listened above.
!
WARNING!
Keep in mind the following specifications.