Bosch Appliances 17e Water Heater User Manual


 
11
Installation/Operating Instructions
Invented for life
TEMPERATURE SELECTOR PAD INSTALLATION DETAILS
Main, Bathroom & Sub Control
Select a suitable flat, dry location away from direct sunlight.(Direct sunlight could
make it difficult to see display)
Cut an opening in wall through center of where the remote control is to be installed,
pull cable from wall cavity through opening. Attach cable to control. Remove cover
from remote control, locate control so that the wiring is not caught between the wall
and the remote control.
Secure control to wall using the screws provided and refit front cover.
Ensure that sufficient cable length is left to remove control if necessary.
TEMPERATURE SELECTOR PAD WIRING DETAILS
1 Remove the front cover of the water heater and locate the PCB on the right hand
side of the cabinet.
2 Locate the two control terminals on the PCB.
(Please be aware that all controller terminals connect back to the same two
points on the PCB)
PRE-SET TEMPERATURE
The Bosch water heaters are factory pre-set to operate at 55°C (or 50°C on 50
degree model) without temperature selector pads. The pre-set temperatures can be
altered to 60°C or 75°C, (or 42°C on 50 degree limited unit) by changing the setting
of the CPU or by using the temperature bridges supplied. Refer to page 13 for
details.
The appliance can also be fitted with temperature selector pads, available as an
accessory item. When fitted, the hot water will be delivered at the temperature
displayed on the selector pad.
There are two versions of remote controls available, the 66 series which has bath fill
alarm and the 67 series which has bath fill stop.
The two different series must never be connected to the same water heater.
The sub controller cannot be used as a sole controller.
There is a Main, Bathroom and Ensuite control available in each series, never
connect more than one of each control type to the water heater (except an extra sub
controller as the fourth controller.)
Only one of each type can be connected to the appliance.
Main controller
YPRM67XBN
YPRM67XB
YPRM66XB
Max temperature 75° C #
Bathroom controller
YPRS67XBN
YPRS67XB
YPRS66XB
Max temperature 50°C
Ensuite controller YPRP62XB YPRP62XB
Max temperature 50°C
67 series (Bathstop) 66 series (Bathfill)
# MAXIMUM TEMPERATURE IS CONTROLLED BY THE MAXIMUM DEFAULT