Bosch Appliances 17e Water Heater User Manual


 
5
Installation/Operating Instructions
Invented for life
TECHNICAL DATA
Nominal hourly gas consumption by proportional gas control:
17e
21e
26e
135 Mj/hr
170 Mj/hr
200 Mj/hr
135 Mj/hr
170 Mj/hr
200 Mj/hr
Natural Gas LP Gas
Test Point Pressure:
Maximum Inlet Water Pressure 1000 kPa
Input voltage single phase 50Hz AC240/230 Volt
Maximum output current 1 Amp
AGA Approval certificate number 7032
Inlet gas connection male thread 20mm
Cold water connection male thread 20mm
Hot water connection male thread 20mm
Relief valve pressure setting 1600 kPa
DATA PLATE
Fitted inside of cabinet
GAS TYPE
The gas type is nominated on a temporary label located on the front cover, and on the data
plate located inside of cabinet. The gas type is the gas on which this appliance is designed to
operate.
DO NOT OPERATE WITH ANY OTHER GAS TYPE.
WARNING LABELS
Located on the right side of the cabinet- PLEASE READ THESE LABELS CAREFULLY!
YS1770RA series
YS2170RA series
YS2670RA series
.67
.69
.72
.26
.21
.19
Natural Gas
Max (kPa)
Model
Natural Gas
Min (kPa)
.78
.91
.80
LP Gas
Max (kPa)
.23
.23
.22
LP Gas
Min (kPa)
Water heating capacity
Litres a minute raised 25°C
17e
17
21e
21
26e
26
25e 200 Mj/hr 200 Mj/hr
YS2670RABZ .72 .19 .80 .22
25e
26