Bosch Appliances 100 Home Security System User Manual


 
Troubleshooting | en 23
Bosch Security Systems, Inc. Firmware Update Manual F.01U.097.269 | 4.0 | 2012.02
3 Troubleshooting
This section provides information for issues that may arise during the upgrade process of an
AutoDome 100, 600, 700 or 800.
3.1 AutoDome 600 Firmware Version Identification
Each service pack contains a version of the files in the illustration below. The version number
of the Service Pack is sequential, but the versions of the firmware modules included in the
service pack varies. Although all files are included in a service pack, only a few of these files
are upgraded with each service pack release.
To display the current versions of the AutoDome 600 firmware files:
Issue the ON-66-ENTER command twice, in quick succession.
The AutoDome displays the current firmware levels for the AutoDome files. Compare
these version numbers to the latest versions identified in the Release Notes, included
with the Service Pack to determine if the AutoDome requires an upgrade.
Figure 3.1 Firmware File Version On-screen Display
Ref. Module Name Filename
1 System Controller (SC) SCMain.G4i
2 AutoTracker/Motion Detection VCA_app.g4i
3 System Controller (SC) Boot SCBootApp.G4i
4 Field Programmable Gate Array (500 series) FPGA_VCA.G4i
5 VCA Boot VCA_boot.G4i
Bosch Security Sys. AutoDome(r)
600 Series
Day/Night 36X
SC Boot
FPGA
VCA_boot
STD Comm
No Heater
FastAddress: Not Set
5.00.00.03/1.05.00.02
1.00.00.00
5.00.00.03
1.13.01.05
1.02.00.01