Bissell 6594 Vacuum Cleaner User Manual


 
Use only BISSELL Replacement Bulbs in your BISSELL
PowerForce Bagless.
Unplug cleaner from electrical outlet
Using a flat screwdriver, table knife or coin, insert into the
slot on the right of the lens and gently push inner latch
to the left as shown to remove the lens.
Standard Bulb – remove the bulb from the socket by
grasping bulb and pulling straight out. Install the new bulb
by pushing it gently into the socket until the bulb snaps
into place.
Large Bulb - remove the bulb from the socket by pushing
bulb in gently and turning it towards brush. Install the new
bulb by pushing it gently into the socket and turning away
from the brush.
Reposition lens, by inserting tab on left side and then
pushing the right side back into place.
Low suction, poor pickup, or no suction may be
due to a clog in the vacuum cleaner. If you notice a
change in the sound of the motor or a reduction in the
spinning action in the Dirt Container, check for clogs.
Unplug cleaner from electrical outlet.
Empty Dirt Container.
Check Upper Tank and Louvers for build up or clogs.
Check to make sure Louvers are installed correctly. To
unlock the Louvers, grasp the rim and turn toward the left.
Pull straight down to remove. If the Louvers are missing
or not locked into place, check and clear the tube in the
center of the Dirt Container.
Remove the Twist ‘n Snap Hose from the vacuum by
turning to the left. Check the Suction Inlet, Hose and Hose
Wand for clogs. Remove any clogs from the hose using a
long, narrow object.
Check the Foot Hose for clogs. If needed, remove the screw
attaching the Hose Wand Base to the vacuum. Straighten
the Foot Hose and unclog with a long, narrow object.
If the clog persists, follow the instructions for Checking
the Rotating Floor Brush on page 10 and inspect the Air
Passageway for obstructions.
1.
Replace Lightbulb
11
2.
3.
4.
1.
2.
3.
4.
5.
6.
Clearing Clogs
Suction
Inlet
Air Passageway
Louvers
Hose
Wand Base
Large Bulb