Bissell 3750, 6595, 6801 Vacuum Cleaner User Manual


 
Place one end of the new Drive Belt over Motor Pulley and the
other end over the Brush in the space between the bristles.
Pull the Brush firmly to stretch the Drive Belt and place ends
of Brush down into slots on sides as shown. Turn Brush
several times by hand to center the Drive Belt.
Reposition Brush Cover and screws. Tighten
screws securely.
Use only BISSELL Replacement Bulb (#203-1007) in
your BISSELL Lift-Off.
Unplug cleaner from electrical outlet.
Remove Detachable Canister and recline Handle of vacuum.
Using a screwdriver, remove the one screw as shown and
lift off the lens.
Remove the bulb from the socket by pushing in gently and
turning it towards brush. Install the new bulb by pushing it
gently into the socket and turning away from brush.
Reposition lens and secure with the one screw.
Select Models Only
The TurboBrush should be checked regularly for clogs
or debris wrapping around the brush roll.
Unplug vacuum from electrical outlet.
If a clog is present or debris is visible, unscrew the two screws
on the back of the TurboBrush to remove the faceplate and
clear any obstructions.
To clean debris from the brush roll, remove the screw located
on the belt cover. Lift the belt cover. Remove the brush roll
from the drive belt and clean debris.
Reposition the drive belt on the brush roll. Place ends of
brush roll in slots on sides as shown. Reposition belt cover
and secure with shorter screw. Reposition faceplate and
secure with two longer screws.
1.
Replace Light Bulb
12
2.
3.
4.
5.
1.
2.
3.
4.
TurboBrush Maintenance
Belt Cover
Rotating Brush and Drive Belt Maintenance Continued
9.
10.
11.
WARNING:
To reduce the risk of electric
shock, turn Power Switch OFF
and disconnect polarized plug
from electrical outlet before
performing maintenance or
troubleshooting checks.
ug603-5540_3750_1004.indd 12ug603-5540_3750_1004.indd 12 11/4/04 11:20:07 AM11/4/04 11:20:07 AM