Bissell 1699 Carpet Cleaner User Manual


 
Bissell PowerSteamer® ProHeat™ Series Service Center Repair Guide
Printed February, 2001
1/30/2004 (Revision 1)
9
2. Make certain the background window has its tabs placed properly.
3. Make certain the gasket is in place on top of the background window.
MOTOR REPLACEMENT PROCEDURE
1. Remove main housing.
2. Rotate upholstery duct back towards handle, letting it rest against the handle.
3. Without disassembling them, remove and set aside the flow indicator and the spray tips
by releasing the tabs and pressing them forward.
4. Remove the pump outlet tube from the motor cover tubing guide located near the motor
shaft.