8
Remove the Belt Access Door. Insert a flathead
screwdriver into the slot nearest the handle to gently
pry off the door (see illustration).
Turn the machine onto its side so the belt access area is
facing upward (see illustrations).
On the bottom of the machine, near the belt access area,
is a White Retainer Plate that holds the black Brush Arm
and brush in place. Using a Phillips head screwdriver
remove the screw that holds the White Retainer Plate in
place. Set White Retainer Plate and Phillips head screw
aside (see illustrations).
Remove the black Brush Arm that holds the brush in
place. Set the black Brush Arm aside (see illustrations).
Locate and remove the broken Pump Belt.
With the unit still on its side, loop one end of the
replacement Pump Belt around the Red Pump Pulley and
the other end around the silver motor shaft (see
illustration). Do not twist the replacement Pump Belt.
Re-install the Brush into the base of the unit.
Place the black Brush Arm onto the Brush and slide
black Brush Arm into original position (see illustrations).
Reattach White Retainer Plate and secure with screw.
To Remove Broken Pump Belt Continued
3.
4.
5.
To Replace Broken Pump Belt
3.
7.
1.
6.
2.
5
4
3
White Retainer Plate
7
6
2
1
3