Power
button
Open the front
panel upward
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips
12
Operation procedures when the remote
control can't be used.
The operation will be started if the power
button is pressed.
If you want to stop operation, re-press
the button.
Forced Operation
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to
operate procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As
Additionally, in order to cancel auto restart operation press power button let it be pressed for about
6 seconds. To operate auto restart operation again, press power button for about 6 seconds as well.
the compressor starts, the fan speed also resumes its previous setting mode.
Heat pump Model
Cooling Model
Room Temp. 24°C 21°C Room Temp. < 24°C Room Temp. < 21°C
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C22°C23°C24°C
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the
value when the fan speed is set to high, and the capacity will
be lower at low or medium fan speed.
High fan speed is recommended when you wish to cool the
room quickly.
High
Speed
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of
room temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be
pressed for about 3 seconds.
If you want to stop the operation, re-press the button.