SIZE:
DRAWN BY:
TITLE: 2 MC-25s WITH ELECTRIC STRIKE,
SEQUENCING 2 DOOR PANELS
A
NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1.
2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF ELECTRIC STRIKE.
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
KJG KJG
80.0147.02
SCALE: DATE:
NONE 16 NOV 2005
PART NO:
SHEET
1 OF 1
24 V
TRANSFORMER
ACTIVATE
COMMON
ACTIVATE
COMMON
BLACK
PURPLE
RED
GRAY
GRAY
BLACK
PURPLE
RED
GRAY
GRAY
COM
N/O
PUSH TO
OPEN
COMMON
N/O
OPTIONAL
A/C ELECTRIC
STRIKE
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM
BRIDGE
RECTIFIER
~~
-
+