Bard P1124A3 Air Conditioner User Manual


 
Manual 2100-353
Page 7
TABLE 4
OPTIONAL FIELD INSTALLED ELECTRIC HEATER TABLE
.gkPretaeH
.oNledoM
stloVtinU
sesahP
&WK.rtH
yticapaC
stloV042@
&WK.rtH
yticapaC
stloV802@
V802/042
spmA.rtH
retaeH
lanretnI
sesuF
BtiucriC
dleiF.oN
stiucriC
.niM
tiucriC
yticapmA
1
revO.xaM
tnerruC
noitcetorP
2
dleiF
rewoP
gniriW
3
dnuorG
eriW
eziSWKHUTBWKHUTB
50A-BP3HE
80A-BP3HE
01A-BP3HE
51A-BP3HE
80A-CP3HE
01A-CP3HE
51A-CP3HE
1-802/042
1-802/042
1-802/042
1-802/042
1-802/042
1-802/042
1-802/042
5
8
01
51
5
01
51
001,71
003,72
001,43
002,15
001,71
001,43
002,15
57.3
00.6
05.7
52.11
57.3
05.7
52.11
008,21
005,02
000,62
004,83
008,21
000,62
004,83
1.81/8.02
8.82/3.33
2.63/6.14
1.45/5.26
1.81/8.02
2.63/6.14
1.45/5.26
06/03
06/03
1
1
1
1
1
1
1
32/62
63/24
64/35
86/97
32/62
64/35
86/97
52/03
04/54
05/06
07/08
52/03
05/06
07/08
01/01
01/01
8/6
4/4
01/01
8/6
4/4
01
01
01
8
01
01
8
50A-BP5HE
01A-BP5HE
51A-BP5HE
02A-BP5HE
1-802/042
1-802/042
1-802/042
1-802/042
5
01
51
02
001,71
001,43
002,15
002,86
57.3
05.7
52.11
00.51
008,21
000,62
004,83
002,15
1.81/8.02
2.63/6.14
1.45/5.26
1.27/2.38
06/03
06/06
1
1
1
1
32/62
64/35
86/97
19/401
52/03
05/06
07/08
001/011
01/01
8/6
4/4
3/2
01
01
8
6
90B-BP3HE
51B-BP3HE
3-802/042
3-802/042
9
51
007,03
002,15
57.6
52.11
000,32
004,83
7.81/7.12
2.13/2.63
1
1
42/82
93/64
52/03
04/05
01/01
8/8
01
01
90B-BP5HE
51B-BP5HE
81B-BP5HE
3-802/042
3-802/042
3-802/042
9
51
81
007,03
002,15
004,16
57.6
52.11
05.31
000,32
004,83
001,64
7.81/7.12
2.13/2.63
5.73/4.34
1
1
1
42/82
93/64
74/55
52/03
04/05
05/06
01/01
8/8
8/6
01
01
01
90C-BP3HE
51C-BP3HE
3-084
3-084
9
51
007,03
002,15
62.8
77.31
002,82
000,74
8.01
0.81
1
1
51
32
51
52
41
01
41
01
90C-BP5HE
51C-BP5HE
81C-BP5HE
3-084
3-084
3-084
9
51
81
007,03
002,15
004,16
62.8
77.31
35.61
002,82
000,74
004,65
8.01
0.81
7.12
1
1
1
51
32
82
51
52
03
41
01
01
41
01
01
Time Delay fuses of HACR type circuit breakers must be used for 60 and smaller sizes. Standard fuses or circuit breakers are suitable for sizes
70 and larger. 480V circuit breakers are not HACR type.
Based on wire suitable for 75 degree C. Other wiring materials must be rated for marked Minimum Circuit Ampacity or greater.
Based upon Table 250-95 of N.E.C. 1993. See electric data for basic heat pump for Circuit A wiring specification requirements.
k
l
j
IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses
and conductor wires in accordance with the National Electrical Code and all existing local codes.