Axor 38000XX1 Plumbing Product User Manual


 
5
Set the high temperature limit stop (optional)
Turn off the water at the supply stops – usually located under
the sink. Turn on the faucet to confirm that the water is off.
Close the drain OR cover it with a wash cloth. Gently pry off
the screw cover or use the 4 mm hex wrench to push the
screw cover into the handle. Retrieve the screw cover when
the handle is removed.
Use a 4mm hex wrench to loosen the handle screw (4 complete revolutions). Remove the
handle. Place the handle in a safe place.
Remove the decorative nut cover and set aside.
Remove the handle screw from the stem of the cartridge.
Remove the high temperature limit stop.
Replace the high temperature limit stop so that the pin on the
cartridge is in the desired slot on the limit stop. Note: the
temperatures given in the diagram assume a water heater
temperature of 140
o
F, a cold water temperature of 50
o
F, and
a water pressure of 45 PSI. Your high temperature may vary.
Replace the decorative nut cover. Replace the handle screw.
Use the hex wrench to turn the screw 4 revolutions.
Replace the handle. Finish tightening the handle screw. Turn on the water and test the
faucet.