5
Set the high temperature limit stop (optional)
• Turn off the water at the supply stops – usually located under
the sink. Turn on the faucet to confirm that the water is off.
• Close the drain OR cover it with a wash cloth. Gently pry off
the screw cover or use the 4 mm hex wrench to push the
screw cover into the handle. Retrieve the screw cover when
the handle is removed.
• Use a 4mm hex wrench to loosen the handle screw (4 complete revolutions). Remove the
handle. Place the handle in a safe place.
• Remove the decorative nut cover and set aside.
• Remove the handle screw from the stem of the cartridge.
Remove the high temperature limit stop.
• Replace the high temperature limit stop so that the pin on the
cartridge is in the desired slot on the limit stop. Note: the
temperatures given in the diagram assume a water heater
temperature of 140
o
F, a cold water temperature of 50
o
F, and
a water pressure of 45 PSI. Your high temperature may vary.
• Replace the decorative nut cover. Replace the handle screw.
Use the hex wrench to turn the screw 4 revolutions.
• Replace the handle. Finish tightening the handle screw. Turn on the water and test the
faucet.