ZC Kit – Large Pellet Insert
(99200149)
Page 4 of 8 10/9/06 © Travis Industries, Inc.
Minimum Enclosure Dimensions
Min. Max. Recommended
Height* 29” 31” ** 30”
Width 36” 43” ** 40”
Depth*** 18” 22” **** 20”
* The enclosure height must be raised the same amount as the floor protection (e.g. if you are using 1” floor
protection, the min. height is 30” above the sub-floor).
** The maximum height is determined by the surround panel size (the surround panels are 32” tall).
*** When determining depth, include the facing material (drywall, tile, etc.) – see the illustration below.
**** When venting vertically, there is no maximum depth.
Width
Depth*
Height
When determining the position of the insert, consider
the position of the framing behind the insert relative to
the vent - see the illustration below.
* When determining the depth, include
the facing material (drywall, tile, etc.).
7.5”
Pellet vent requires 3”
clearance to combustibles.
TOP VIEW
NOTE: The enclosure may be
raised. The minimum
distance from the base of the
enclosure to the ceiling is 72”
Ceiling